background image

 

Page 44 of 54

 

INSTRUCTION MANUAL

 

SGTEL-168

 TELECOM LINE SURGE GENERATOR 

 

1912 1 E l T o ro R d  

   Si l vera do,  Ca lifo rni a 9 26 76  

  (9 49)  459 -96 00   

  co m-p o wer. com

 

 

REV070516 

 

7.1.1 Menu 

Bar 

The menu bar has three pull-down menus; 

File

Connect Device

 

and 

Help

7.1.1.1 File 

Menu 

 
 
 

The 

File

 pull-down menu functions 

in same manner as most windows-

based software.  It contains the 
following options: 

MENU ITEM DESCRIPTION 

New 
Sequence 

Upon creation of a new sequence, 

TransWare™

 will 

prompt you to save any active sequence before 
opening a blank template on which you can create 
your desired sequence.

 

Load 

Sequence 

Opens dialog box from which the user can navigate 
directory system in order to open a previously saved test 
sequence (with .cpc extension).

 

Save 

Sequence 

This function re-saves the sequence under the same file 
name and directory path.

 

Save As 

Opens dialog window from which the user can navigate 

directory system, assign a file name and save the active 
test sequence (with .cpc extension).

 

Print 
Sequence 

Opens the ‘print’ dialog window, from which the user 
can print the active test sequence. 
If the sequence has previously been saved, the file 
name under which the sequence was saved is used as 
the title of the sequence table. If the sequence has not 
been saved, the user is prompted to assign a title for the 
sequence table.

 

Exit 

After prompting the user to save changes to any active 
sequence, exits the 

TransWare™

 software.

 

NOTE:

 

Care must be taken that the software is not closed when the tasks are 

running.  Although for safety reason, we do send a ‘Stop’ command as well as 
‘Switch to Local’ command in case if GUI is closed by mistake or any reason.

 

1

Содержание SGTEL-168

Страница 1: ...54 INSTRUCTION MANUAL SGTEL 168 TELECOM LINE SURGE GENERATOR 19121 El Toro Rd Silverado California 92676 949 459 9600 com power com REV070516 INSTRUCTION MANUAL for TELECOM LINE SURGE GENERATOR Model...

Страница 2: ...EL 168 System Power Input Port 14 4 1 1 1 System Power Input Port Fuse 14 4 1 2 Equipment Under Test EUT Power Input Port 15 4 1 2 1 Turning ON OFF EUT Power LOCAL Control 16 4 1 2 2 Turning ON OFF EU...

Страница 3: ...s 34 5 4 2 1 Measurement of Current Waveform Parameters 35 5 4 2 2 Example calculations for Current Waveform Parameters 36 6 0 Controlling the SGTEL 168 via its Front Panel 37 6 1 Self Test 37 6 2 Sur...

Страница 4: ...tion 18 FIGURE 7 Remote Interface Setup Example 19 FIGURE 8 Coupling Example for Type A 800V metallic Surge 23 FIGURE 9 Coupling Example for Type A 1500V longitudinal Surge 24 FIGURE 10 Coupling Examp...

Страница 5: ...nt and rear panel ports controls and indicators product specifications safety precautions operational instructions and warranty information and guidelines and instructions for its proper usage Informa...

Страница 6: ...works CDN Comb Generators Current Probes Emissions Test Systems Conducted Immunity Test Systems Impedance Stabilization Networks ISN Line Impedance Stabilization Networks LISN Antenna Masts Near Field...

Страница 7: ...ckage inventory in section 3 2 to ensure that you have received all applicable items 3 2 Package Inventory STANDARD ITEMS 9 SGTEL 168 Telecom Line Surge Generator 9 Safety Interlock Port Key 4 pin 7mm...

Страница 8: ...e instrument on a wall or ceiling VENTILATION The instrument should be situated so that its location or position does not interfere with its proper ventilation Do not install in a cabinet or in other...

Страница 9: ...e there are gas fumes Never use equipment that is operating in a strange manner or that shows clear indication of abuse If probes are in use be sure they are differential probes which have no ground c...

Страница 10: ...s 6 These six LED indicators provide the present instrument status for the SGTEL 168 System Power Switch 7 This switch toggles ON OFF the SGTEL 168 surge generator Fiber Optic Connector for Remote Int...

Страница 11: ...source enters the generator EUT Power Input Port 14 This port connects to the EUT power source See section 3 5 for input power specifications SGTEL 168 System Power Input Port 15 This port connects to...

Страница 12: ...actual V measured 1000 Current Monitoring Port Imon 100 1 10 I V measured 100 0 01 Volts Amp Sync Output Port 0 5 VDC Electrical System Power Input 100 250 VAC rms 50 60 Hz 300 VA Max Fuse Type 5 Amps...

Страница 13: ...Page 13 of 54 INSTRUCTION MANUAL SGTEL 168 TELECOM LINE SURGE GENERATOR 19121 El Toro Rd Silverado California 92676 949 459 9600 com power com REV070516 FIGURE 3 Product Dimensions...

Страница 14: ...he following power source Voltage 100 250 VAC Frequency 50 60 Hz Power 300VA Maximum In accordance with international safety standards this instrument is equipped with a three wire power cable When co...

Страница 15: ...L 168 SURGE GENERATOR DISCONNECT POWER FROM EUT POWER INPUT PORT WHEN POWERING ON OR OFF THE GENERATOR ASSEMBLED ASSEMBLED CONNECTOR CONNECTOR ROTATE STRAIN ROTATE STRAIN RELEIF RELEIF COUNTER COUNTER...

Страница 16: ...s internal CDN output terminals If the EUT power is not enabled on the SGTEL 168 front panel the following message will be displayed If the SGTEL 168 uses an power frequency phase detection circuit to...

Страница 17: ...OWER button The SGTEL 168 surge generator will automatically check the EUT power status at the start of any test or test sequence which includes surges applied to its internal CDN output terminals If...

Страница 18: ...cases where no interlock switch is used simply connect the safety interlock key right to this port to enable the generator For those cases where use of an external switch as the safety interlock is de...

Страница 19: ...end of the fiber optic cable into the powered OTA 232 Optical Transreceiver Adapter Finally connect the OTA 232 Adapter to a computer with the Com Power TransWare software installed FIGURE 7 Remote I...

Страница 20: ...ative of the voltage at the surge output terminals with a typical accuracy within 10 However the actual wave shape of the surge waveform may become distorted and therefore this port should not be used...

Страница 21: ...ne CDN output port is fitted with a Universal Multi Configuration AC Socket CAUTION Due to the presence of DANGEROUS VOLTAGES the user should avoid all contact with these output port as well as any ca...

Страница 22: ...Figures 8 9 10 11 and 12 Where it is not practical to fit each line to be tested with safety socket connectors alternative means of connection such as break out boxes can be very convenient in many c...

Страница 23: ...ghtning surges may occur including for example a tip to ring b tip 1 to ring 1 and c for a 4 wire connection that uses simplex signaling tip to ring 1 and ring to tip 1 The SGTEL 168 applies this surg...

Страница 24: ...for example a tip ring pair to earth b tip 1 ring 1 pair to earth and c to all leads intended for connection to non approved equipment connected together The SGTEL 168 applies this surge between Termi...

Страница 25: ...htning surges may occur including for example a tip to ring b tip 1 to ring 1 and c for a 4 wire connection that uses simplex signaling tip to ring 1 and ring to tip 1 The SGTEL 168 applies this surge...

Страница 26: ...his includes for example d tip ring pair to earth e tip 1 ring 1 pair to earth and f to all leads intended for connection to non approved equipment connected together The SGTEL 168 applies this surge...

Страница 27: ...phase AC powered devices up to 16 amps For devices drawing greater than 16 amps of current and or devices requiring a 3 phase power system a compatible Com Power external CDN is required which connect...

Страница 28: ...input 4 Coaxial cables adapters and or fixtures as necessary so that all required connections are made properly 5 2 Surge Waveform Measurements As discussed in the following sections open circuit vol...

Страница 29: ...s Examples of typical measurement connection arrangements at the surge output ports of the SGTEL 168 for both open circuit voltage left and short circuit current right are shown below in Figures 13 14...

Страница 30: ...rchangeably Given in Table I below are the limit ranges for the individual waveform parameters for each surge type TABLE I Surge Waveform Requirements Waveform Parameter Type A 800V Type A 1500V Type...

Страница 31: ...igure 16 defines the open circuit voltage wave shape FIGURE 16 Open Circuit Voltage Wave Shape TABLE II Open Circuit Voltage Waveform Requirements Waveform Parameter Type A 800V Type A 1500V Type B 10...

Страница 32: ...e measurement of T which is defined below T Time difference between A the first point on the rising slope of the waveform at or above 30 of Vpk and B the first point on the rising slope of the wavefor...

Страница 33: ...MEASURED VALUES Vpk 1525 2 Volts Limit Range 1500 1575V V 30 pk 457 56 Volts T 30 pk 0 328 s V 90 pk 1372 7 Volts T 90 pk 4 515 s V 50 pk 762 60 Volts T 50 pk 222 5 s Based on these measured values t...

Страница 34: ...Figure 17 defines the short circuit current wave shape FIGURE 17 Short Circuit Current Wave Shape TABLE III Short Circuit Current Waveform Requirements Waveform Parameter Type A 800V Type A 1500V Type...

Страница 35: ...the first point on the rising slope of the waveform at or above 10 of Ipk and B the first point on the rising slope of the waveform at or above 90 of Ipk Tr 1 25 x T DECAY TIME The Decay Time Td or fa...

Страница 36: ...ed MEASURED VALUES Ipk 218 284 Amps Limit Range 200 230A I 10 pk 21 828 Amps T 10 pk 0 101 s I 90 pk 196 46 Amps T 90 pk 6 789 s I 50 pk 109 14 Amps T 50 pk 166 075 s Based on these measured values th...

Страница 37: ...on controlling the SGTEL 168 using TransWare 6 1 Self Test Each time the SGTEL 168 is turned on it will automatically perform a three stage self test 1 SWITCHING RELAYS ON OFF During first stage of Se...

Страница 38: ...event s RUN the test Each of these functions are explained in detail in the following sections 6 2 1 Surge Menu Items 6 2 1 1 Surge Type S U R G E T Y P E A 0 8 0 0 The top line of the display SURGE...

Страница 39: ...the keys to switch between digits as diagrammed below 0 0 1 Once you have entered the desired number of surges press the key 6 2 1 4 Delay Time Between Surges T E S T S 0 0 1 0 7 4 s On the right side...

Страница 40: ...this menu screen will save the presently defined parameters into one of the ten available non volatile memory locations The test is saved under an automatically assigned name based on the defined par...

Страница 41: ...y is the difference between the charging time for the current surge type and the delay time between surges If the delay time between surges has been set to minimum default value then the pulse delay w...

Страница 42: ...uring the test pressing the key will abort the test process T E S T S 1 1 0 0 0 s S T A T U S A B O R T E D After aborting the test press key to restart the same test or press the key to return to the...

Страница 43: ...M LINE SURGE GENERATOR 19121 El Toro Rd Silverado California 92676 949 459 9600 com power com REV070516 7 0 TransWare Software 7 1 Main Screen The layout of the main screen is as shown in Figure 18 FI...

Страница 44: ...extension Save Sequence This function re saves the sequence under the same file name and directory path Save As Opens dialog window from which the user can navigate directory system assign a file nam...

Страница 45: ...en the connection has been made the Communication status at the bottom left corner of the TransWare window will change from to This indicates that the unit is in its remote operating mode In this mode...

Страница 46: ...and editing surge events is done using the SEQUENCE EDITING FUNCTIONS which is accessed by selecting the EDIT SEQUENCE option on the TASK OPTIONS panel see section 7 1 4 Surge events are displayed in...

Страница 47: ...t the waveform for a given surge event Polarity This 2 item pull down menu toggles the polarity of the surge between POSITIVE and NEGATIVE Surge Output Coupling This pull down menu is used to select t...

Страница 48: ...ich of the two main functions is selected Shown to the right is the TASK OPTIONS menu When EDIT SEQUENCE is selected the sequence editing functions are displayed on this panel see section 7 1 4 1 When...

Страница 49: ...cal values to the selected surge event Remove 1 Removes the selected surge event s from the sequence Move Up 1 Moves the selected surge event s upward by one row in the sequence Move Down 1 Moves the...

Страница 50: ...enu Here the user can create a test log after which he she can edit view and enter comments into the test log FUNCTION BUTTON DESCRIPTION Create Test Log Opens a form window with fields for Company Na...

Страница 51: ...the left and described below FUNCTION BUTTON DESCRIPTION View Active Test Opens the active log form displaying entered comments and surge details Enter Comments Into Log Allows the user to enter notes...

Страница 52: ...test Prior to starting the test the controls area appears as shown to the right and as described below FUNCTION BUTTON DESCRIPTION The EUT power button enables disables the EUT power output on the int...

Страница 53: ...st was paused press the button again The STOP button aborts the active test Test cannot be resumed after aborting Changes the TransWare window to a smaller compacted repositionable window while still...

Страница 54: ...pair damage resulting from attempts to install repair service or modify the instrument by personnel other than Com Power service representatives Under no circumstances does Com Power recognize or assu...