Com-Power CDN-AF4 Скачать руководство пользователя страница 4

Model  CDN -AF4

Operating Enviroment

The instrument has been designed for indoor use only.  It should
not be used in damp or wet enviorment.  The permissible
ambient temperature range during operation is +10°C (+50°F)
to +40°C (+104°F). Please read the safety section.

Maintenance

There are no user serviceable parts inside these units. If the
unit does not operate or needs calibration, please return it to
the factory. Do not open instrument cover. Any modifications or
repairs performed on the unit by someone other than a
auhorized factory trained technician will void warranty.

The exterior surface may be cleaned with mild detergent and
then be wiped with a dry clean lint-free cloth. Do let any cleaning
agent seep into into the chassis.

IV

Содержание CDN-AF4

Страница 1: ...Model CDN AF4 COUPLING DECOUPLING NETWORK MODEL CDN AF4...

Страница 2: ...nnel other than Com Power service representative Under no circumstances does Com Power recognize or assume liability for any loss damage or expense arising either directly or indirectly from the use o...

Страница 3: ...nductors to the mains should not be connected until all the connections to the EUT CDN auxilary equipement and test equipment are completed Test personnel should not touch any exposed test leads or te...

Страница 4: ...ce There are no user serviceable parts inside these units If the unit does not operate or needs calibration please return it to the factory Do not open instrument cover Any modifications or repairs pe...

Страница 5: ...meters 2 3 3 0 Calibration 2 3 4 0 Establishing drive table 2 4 4 1 Setting levels 2 5 3 Theory of Operation 3 1 3 0 Overview 3 1 3 1 Typical test setup 3 1 List of Figures Figures page 1 1 CDN AF4 Ph...

Страница 6: ...CDN AF4 Coupling Decoupling networks CDN is intended for testing products according to EN61000 4 6 standard for immunity to conducted disturbance induced by radio frequency fields from 150 kHz 80 MHz...

Страница 7: ...max Voltage attenuation RF EUT 9 dB to 12 dB Insertion loss EUT AE 30 dB min from 150 kHz to 2 MHz 50 dB min from 2 MHz to 80 MHz Coupling factor 0 dB 1 dB 2 dB Decoupling attenuation RF AE 50 dB min...

Страница 8: ...Model CDN AF4 Figure 1 2 CDN Model CDN AF4 typical common mode impedance 1 3...

Страница 9: ...Model CDN AF4 Figure 1 3 CDN Model CDN AF4 typical attenuation factor graph 1 4...

Страница 10: ...Model CDN AF4 Figure 1 4 CDN Model CDN AF4 typical Coupling factor graph 1 5...

Страница 11: ...ources electromagnetic disturbance which may couple to shield of signal cables 2 1 CDN requirements The CDN AF4 coupling and decoupling network Allows Coupling of the disturbing signals to the equipme...

Страница 12: ...ort of the CDN are given in table 2 1 This ensures that any circuit level abnormal operation was caused by the injected RF signal on the EUT and not the auxillary equipment AE The requirement must be...

Страница 13: ...easured at the factory and supplied with each unit However if you wish to check the attenuation and coupling factor on site you could purchase optional calibration kit which includes the shorting bars...

Страница 14: ...modulated disturbing signal levels expressed in r m s Figure 2 5 Level measurement setup using CDN Table 2 2 Test Levels specified by IEC 1000 4 6 2 4 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 1...

Страница 15: ...lue Next turn on the power amplifier and signal generator and take the measurements from 150 kHz 80 MHz for each level with CW unmodulated The rate of the sweep shall not exceed 1 5 x 103 decades seco...

Страница 16: ...ded conductors Other types CDN may be necessary to couple and decouple different types of cables that may connected to the EUT Such as coax shielded cables and powerline Please see connection diagram...