2.0 Overview
Com-Power CDN-AF4 allows coupling of RF CW and
modulated voltages into equipment throught the shield of four
conductor signal cables. This CDN was built to meet the
requirments of IEC-1000-4-6. This CDN-AF4 can be used to
verify that electronic equipment are not susceptible to sources
electromagnetic disturbance which may couple to shield of
signal cables.
2.1 CDN requirements
The CDN-AF4 coupling and decoupling network:
•
Allows Coupling of the disturbing signals to the
equipment under test.
•
Provides stable impedance to the equipment under test
independent of the auxillary equipment common mode
impedance.
•
Prevents interference to the auxillary equipment by
decoupling the disturbing signals.
•
Does not interrupted signals to the EUT
The Com-Power CDN-AF4 meet the following parameters
specified by IEC-1000-4-6 specifications.
2-1
Table 2-1 Coupling Decoupling Device Parameters
2