4.7 Troubleshooting and remedy
Fault
Cause
Remedy
Machine cannot be started
with AUTOSTART
Lifting spindles (22) are not in
end position
Press LOWER key (11) once again
Machine cleans poorly
Spray nozzle (36) is blocked
Clean spray nozzle (36)
Brushes (1) are soiled
Clean brushes (1)
Brushes (1) are worn
Replace brushes (1)
Detergent return to the ma-
chine is too low
Seal strip (34) is defect
Replace seal strip (34)
Stripping brush (33) is dirty
Open the e.g. the left cover for the
suction sump (48) and clean strip-
ping brush (33)
Dirt streaks are visible on
front face
Stripping brush (33) is dirty
Open the e.g. the left cover for the
suction sump (48) and clean strip-
ping brush (33)
Stripping brush (33) is worn
Open the e.g. the left cover for the
suction sump (48) and clean strip-
ping brush (33)
Water residues on escalator
Cover (28) of dirty-water tank
(21) does not close tight
Attach cover (28) anew
Cover (28) of dirty-water tank
(21) does not close tight
Replace tank cover
If the fault in the machine cannot be remedied according to the procedures
described in the table above, the customer service of columbus should be no-
tified and the necessary repair work carried out by its staff.