Figure 22 Wear measurement chain drive
Figure 23 Tightening the chains
4.6.2 Cleaning and replacing fresh water nozzles
(see Fig. 21: Chain drive / spray nozzle)
Screw off coupling ring (16).
Remove pressure spring (41), spray nozzle (36) and ball (40).
Clean spray nozzle, using only instruments without sharp edges.
Re-assemble fresh-water nozzle as shown in illustration, while making sure:
The spray nozzles must be aligned in their mounting according to the turning
safety device! The coupling ring (42) should only be twisted on manually!