INSTALLATION & USER'S MANUAL CLITE2
Page 47
Info
15.6
This menu shows information that is needed to be known during support from Colorlight or if any
optional functions should be added to the operator panel after purchase (more about this under
).
Status
15.7
This menu will give information in form of text messages if there is errors.in the system, it also
contains
a “
Lamp-hour counter
” showing the accumulated total running time in hours for each
LED-module.
Errors can be reset from this menu by simply press the button marked “
Dismiss
”, if errors
persist despite resetting, contact Colorlight.
Message
Fault
Remedy
Communication error
CAN bus transmission issues
Check for loose wires in the
electrical box and contact
Colorlight.
Over current
Overcurrent protection triggered,
movement blocked
Check that the searchlight is able
to rotate freely.
In winter, heavy icing can be the
cause of this error.
Over voltage
Overvoltage protection triggered,
voltage to searchlight motordriver/s
have exceeded 40Vdc.
Reset the error, if error recurs
repeatedly, please contact
Colorlight.
Under voltage
Undervoltage protection triggered,
voltage to searchlight motordriver/s
has fallen below 8,5Vdc
Reset the error, if error recurs
repeatedly, please contact
Colorlight.
Содержание CLITE2
Страница 57: ...INSTALLATION USER S MANUAL CLITE2 Page 57 OP Rotation illustration 270 0 90 180...
Страница 66: ...Page 66 INSTALLATION USER S MANUAL CLITE2 Mechanical drawings 17 2 Operator Panel 17 2 1...
Страница 67: ...INSTALLATION USER S MANUAL CLITE2 Page 67 Electrical box CLITE2 100 240VAC 17 2 2...
Страница 68: ...Page 68 INSTALLATION USER S MANUAL CLITE2 Electrical box CLITE2 24VDC 17 2 3...
Страница 74: ...Page 74 INSTALLATION USER S MANUAL CLITE2 CLITE2IR VIDEO CONNECTION 19...
Страница 86: ...Page 86 INSTALLATION USER S MANUAL CLITE2...
Страница 87: ...INSTALLATION USER S MANUAL CLITE2 Page 87...