DYNAX
450
Collomix GmbH
14
Version 1.6-18
7.
Errors and Troubleshooting
The troubleshooting tables in this Chapter will help you to determine whether you can troubleshoot yourself or whether you need to call
customer service.
DANGER
Danger of death by dangerous voltage
Please note that all maintenance and servicing jobs must be left strictly to authorized and suitably
trained expert staff. This applies in particular to those jobs printed on a gray background which
have to be performed with the housing open.
7.1
Possible errors
Fault
Description
Machine condition
Solutions
E010
Door open
•
Door open
•
Close door
•
Door closed
•
Check the door lock
•
Check the power cord / plug to the door lock.
E020
EMERGENCY STOP
activated
•
EMERGENCY STOP button pushed
•
Release the EMERGENCY STOP
•
EMERGENCY STOP button not
pushed
•
Check the switch of the EMERGENCY STOP button
•
Check the power cord / plug to the EMERGENCY STOP
button.
E050
Defective container
•
Container is defect
•
Container is unstable
•
Check clamping pressure, if necessary adjust
E070
Mixing Unit locked
•
Latching pin blocked
•
The latching pin is blocked – clean and lubricate,
replace if necessary
•
Latching pin released
•
Check the lead/connector to the switch of the mixing
unit lock.
•
The switch of the mixing unit lock is defective.
E080
Mixing Unit unlocked
•
Latching pin blocked
•
The mixing unit is not 12 at o'clock position
•
Check the lead/connector to the switch of the latching
pin
•
The switch of the mixing unit lock is defective
•
Latching pin released
•
Check the lead/connector to the switch of the mixing
unit lock.
•
The switch of the mixing unit lock is defective
E120
Mixing speed too low
•
The mixing unit rotates
•
Check the lead/connector to the "position"
•
proximity switch
•
The "position" proximity switch is defective
•
The mixing unit does not rotate
•
Check frequency converter
•
Check the door safety switch
•
Check the main motor
E130
Mixing speed too high
•
The mixing unit rotates too fast
•
Decrease the motor speed
E150
Error clamp motor
•
The mixing container is not
clamped
•
Check the clamp motor
•
Check the lines to the clamp motor
•
Check the control
Содержание DYNAX 450
Страница 2: ...DYNAX 450 Collomix GmbH 2 Version 1 6 18 ...
Страница 20: ...DYNAX 450 Collomix GmbH 20 Version 1 6 18 11 2 Dimensions ...
Страница 22: ...DYNAX 450 Collomix GmbH 22 Version 1 6 18 ...
Страница 23: ...Collomix GmbH DYNAX 450 Version 1 7 18 23 ...