Collomix GmbH
Shaker
AGIA 200, VIBA 300 & VIBA 330
D-85080 Gaimersheim
Version G 1.4-16
15
7.2
Unlock door manually
The machine is equipped with a safety lock, which locks the door automatically after it is closed. In
the event of a malfunction or power outage, the door can be locked manually.
•
Remove the plastic stopper (6) from the door unlocking device.
•
Use a screwdriver to turn the unlocking device in direction of the arrow.
•
Open the door.
8.
Cleaning, maintenance, and service
It is necessary to check, clean, and service the machine regularly to ensure continuous function.
Unplug the machine from power by pulling the plug before all cleaning, maintenance, and repair
work is done on the machine.
8.1
Cleaning
Remove any spilled mixed compound immediately from the interior of the machine. For this
purpose use a rag or a scraper. Be careful not to damage any connections or sensors.
Never use solvent cleaning agents, acetone, gasoline or similar aggressive substances to clean the
window in the door or the control panel. Such substances can corrode or even destroy plastic
parts.
Soiled threaded spindles can be cleaned with a rag or a wire brush. The threaded spindles must be
re-lubricated with
Mobilux EP2
after cleaning.
CAUTION
Damage to the machine through dry run ball bearings
If you clean the machine with a high-pressure washer, the lubricant is washed out from the ball
bearings and they run try.
•
Never clean the machine with a high-pressure washer or similar.
•
Replace dry-run ball bearings immediately.
8.2
Maintenance
Only qualified personnel may carry out maintenance and repair work. Use only original replacement
parts.
8.2.1
Annual maintenance
Clean the threaded spindles and lubricate with Mobilux EP2.
Check the outer flange bearings and swing arms for damages.
Check the drive belt for wear and tear and adjust the belt tension if needed.
Check connections to the drive motor and clamp motor for wear and tear. Replace if needed.
Check the door lock for wear and tear.
Check the clamping table (3) for wear and tear. Replace if needed.
8.2.2
30,000-cycle service
Drive belts and flange bearings of the mixing unit must be replaced by an authorized service
technician every 30,000 mixing cycles but no later than after 1,000 operating hours.
The number of cycles and the operating hours are shown on the LC display of the operating unit
during the initialization after the machine is turned on.