background image

 

Collomix GmbH 

 

Shaker 

AGIA 200, VIBA 300 & VIBA 330

 

D-85080 Gaimersheim 

 

Version G 1.4-16

 

15 

7.2

 

Unlock door manually 

The machine is equipped with a safety lock, which locks the door automatically after it is closed. In 

the event of a malfunction or power outage, the door can be locked manually. 

 

 

Remove the plastic stopper (6) from the door unlocking device. 

 

Use a screwdriver to turn the unlocking device in direction of the arrow. 

 

Open the door. 

 

 

 

8.

 

Cleaning, maintenance, and service 

It is necessary to check, clean, and service the machine regularly to ensure continuous function. 

Unplug the machine from power by pulling the plug before all cleaning, maintenance, and repair 

work is done on the machine. 

8.1

 

Cleaning 

Remove any spilled mixed compound immediately from the interior of the machine. For this 

purpose use a rag or a scraper. Be careful not to damage any connections or sensors. 

Never use solvent cleaning agents, acetone, gasoline or similar aggressive substances to clean the 

window in the door or the control panel. Such substances can corrode or even destroy plastic 

parts. 

Soiled threaded spindles can be cleaned with a rag or a wire brush. The threaded spindles must be 

re-lubricated with

 Mobilux EP2

 after cleaning. 

 

CAUTION 

Damage to the machine through dry run ball bearings 

If you clean the machine with a high-pressure washer, the lubricant is washed out from the ball 

bearings and they run try. 

 

Never clean the machine with a high-pressure washer or similar. 

 

Replace dry-run ball bearings immediately. 

8.2

 

Maintenance 

Only qualified personnel may carry out maintenance and repair work. Use only original replacement 

parts. 

8.2.1

 

Annual maintenance 

 

Clean the threaded spindles and lubricate with Mobilux EP2. 

 

Check the outer flange bearings and swing arms for damages. 

 

Check the drive belt for wear and tear and adjust the belt tension if needed. 

 

Check connections to the drive motor and clamp motor for wear and tear. Replace if needed. 

 

Check the door lock for wear and tear.  

 

Check the clamping table (3) for wear and tear. Replace if needed. 

8.2.2

 

30,000-cycle service 

Drive belts and flange bearings of the mixing unit must be replaced by an authorized service 

technician every 30,000 mixing cycles but no later than after 1,000 operating hours.  

The number of cycles and the operating hours are shown on the LC display of the operating unit 

during the initialization after the machine is turned on.   

 

 

Door unlocking device 

Содержание AGIA 200

Страница 1: ...Version G 1 4 16 Instructions Shaker AGIA 200 VIBA 300 VIBA 330 Keep this manual within immediate reach of the machine Translation of the original instructions en Englisch...

Страница 2: ...Shaker AGIA 200 VIBA 300 VIBA 330 Collomix GmbH D 85080 Gaimersheim 2 Version G 1 4 16...

Страница 3: ...t time 10 5 1 Content 10 5 2 Transport 10 5 2 1 Attach transport lock 10 5 2 2 Remove transport lock 11 5 3 Set up the equipment 11 5 4 Trial run 11 6 Operation 12 6 1 Switching on the machine 12 6 2...

Страница 4: ...ion G 1 4 16 1 Layout Drawings 1 1 Machine components Machine components 1 Power supply and fuse 6 Manual door release 2 Mixing table 7 Operating unit CSE 3 Clamping plate 8 Door 4 Main switch 9 Loadi...

Страница 5: ...aimersheim Version G 1 4 16 5 1 2 Operating and display components Button for DOOR OPEN door Button E OPEN the mixing unit STOP stop mixing cycle prematurely ACKNOWLEDGE messages Button I Mixing cycle...

Страница 6: ...t paying attention to the corresponding precautionary measures WARNING This signal word is used if death or severe physical injuries may result from not paying attention to the corresponding precautio...

Страница 7: ...Operating Instructions before working with the machine Keep the Operating Instructions within immediate reach of the machine Please hand the Operating Instructions to any subsequent owners 3 1 General...

Страница 8: ...vious with obvious malfunctions Repair cleaning and maintenance work without disconnecting the system from power WARNING Danger of injury through improper modifications Hazards exist through unauthori...

Страница 9: ...ne if needed 3 6 Residual Risks If all precautions are taken there may be obvious residual risks Adhering to the safety instructions the designated use and the operating instructions as a whole can re...

Страница 10: ...ances in an ergonomically user friendly manner The door must be opened for the machine to be handled safely during transport Secure the opened door with the hand against swinging 5 2 1 Attach transpor...

Страница 11: ...ately upon receipt and the equipment when unwrapping it for any visual external defects Keep all parts of the original packaging for a possible necessary return Remove the machine from the pallet with...

Страница 12: ...isplay Any errors detected during initialisation are shown in text form on the display 6 2 Load a container To place the container proceed as follows Open the door by pushing the DOOR button To adjust...

Страница 13: ...e mixing process can be stopped early by pushing the E button 6 5 EMERGENCY STOP switch In dangerous situations the machine can be turned off with the EMERGENCY STOP switch After the machine is turned...

Страница 14: ...otor Door engages Check the micro switch of the door lock E030 Did not find the container No mixing container is placed Place mixing container Mixing container is placed The mixing container is too sm...

Страница 15: ...aned with a rag or a wire brush The threaded spindles must be re lubricated with Mobilux EP2 after cleaning CAUTION Damage to the machine through dry run ball bearings If you clean the machine with a...

Страница 16: ...transport package is made of recyclable material Please dispose this material accordingly At the end of the useful life the machine must be properly disposed to return the used raw materials to the r...

Страница 17: ...kg Maximum container weight 40 kg 40 kg 40 kg Maximum container height 50 300 mm 50 400 mm 50 400 mm Maximum container footprint w x d 370 330 mm 370 330 mm 370 330 mm Machine weight 135 kg 150 kg 15...

Страница 18: ...05 AC 2005 in accordance with the requirements of the guidelines 2006 95 EC 2004 108 EC 19 04 2016 2014 30 EU 20 04 2016 2006 42 EC Please request technical information from Collomix GmbH Abt Technisc...

Страница 19: ...Collomix GmbH Shaker AGIA 200 VIBA 300 VIBA 330 D 85080 Gaimersheim Version G 1 4 16 19...

Страница 20: ...haker AGIA 200 VIBA 300 VIBA 330 Collomix GmbH D 85080 Gaimersheim 20 Version G 1 4 16 Collomix GmbH Daimlerstr 9 85080 Gaimersheim Germany Tel 49 0 8458 32 98 0 Fax 49 0 8458 32 98 30 www collomix de...

Отзывы: