5005749-CTG-A-0216
66
Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
TH4B4821S
AIR TEMP.
ENTERING
OUTDOOR UNIT (°F)
AIR TEMP.
ENTERING
INDOOR COIL (°F)
ID CFM
1400
1600
1800
MBH
COP
KW
MBH
COP
KW
MBH
COP
KW
60
60
59.2
4.49
3.86
60.0
4.65
3.78
60.9
4.82
3.70
70
58.2
3.93
4.34
59.0
4.08
4.23
59.7
4.25
4.12
80
57.2
3.49
4.81
57.9
3.63
4.67
58.6
3.79
4.53
47
60
51.1
4.12
3.63
51.4
4.22
3.57
51.7
4.31
3.51
70
50.1
3.59
4.08
50.4
3.68
4.01
50.8
3.79
3.93
80
49.1
3.17
4.54
49.5
3.27
4.44
49.9
3.36
4.35
40
60
45.7
3.86
3.47
46.6
3.96
3.45
47.5
4.06
3.43
70
45.5
3.37
3.95
46.2
3.47
3.90
46.9
3.57
3.85
80
45.3
2.99
4.44
45.8
3.08
4.36
46.4
3.18
4.28
30
60
40.0
3.52
3.33
40.5
3.59
3.31
41.1
3.66
3.29
70
39.5
3.11
3.73
39.9
3.17
3.69
40.2
3.23
3.65
80
39.1
2.77
4.14
39.2
2.82
4.08
39.3
2.87
4.02
17
60
29.6
2.94
2.95
31.9
3.05
3.06
34.1
3.15
3.17
70
30.9
2.59
3.50
32.3
2.67
3.54
33.7
2.76
3.58
80
32.2
2.33
4.04
32.7
2.39
4.01
33.3
2.45
3.98
10
60
30.0
2.85
3.08
29.9
2.85
3.08
29.93
2.85
3.08
70
29.2
2.52
3.40
29.2
2.53
3.38
29.1
2.53
3.37
80
28.5
2.25
3.71
28.4
2.26
3.68
28.3
2.27
3.66
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (O INDOOR).
Yellow shaded cells are AHRI High Heating conditions.
Orange shaded cells are AHRI Low Heating conditions.
COIL MULTIPLIERS - 4 TON
Air Handler
Coil
MBH
COP
KW
–
CF/CM/CU60C
0.94
0.96
0.98
–
CF/CM/CU60D
0.94
0.96
0.98
AE48CX21
–
0.95
1.00
0.95
AE48DX21
–
0.95
1.01
0.94
AE60CX21
–
0.95
1.01
0.94
AVC48CX21
–
0.94
0.96
0.98
AVC48DX21
–
0.95
1.00
0.95
AVC60CX21
–
0.94
0.96
0.98
ME14DN21
CF/CM48D
0.95
1.00
0.95
ME14DN21
CF/CM60D
0.96
0.98
0.97
ME16CN21
CF/CM48C
0.95
1.00
0.95
ME16CN21
CF/CM60C
0.95
1.00
0.95
ME20DN21
CF/CM48D
0.95
1.00
0.95
ME20DN21
CF/CM60D
0.95
1.00
0.95