background image

25

11.  

CUSTOMER AND TECHNICAL SUPPORT

 

For help and support in using this product, please contact Customer Services at the following

 address:

 

Antylia Scientific Ltd.

 

Beacon Road,

 Stone,
 Staffordshire,
 

ST15 0SA,

 

United Kingdom

 

Tel: +44 (0)1785 812121

 

Service: [email protected]

 

General enquiries: [email protected]

 

Order enquiries: [email protected]

 

Technical support: [email protected]

 
 www.coleparmer.com

Содержание SHM-250 Series

Страница 1: ...Cole Parmer SHM 250 Series Digi Mantle Instruction Manual M7754 Version 14 6...

Страница 2: ...ction manual is the property of Antylia Scientific Limited This instruction manual is supplied by Antylia Scientific Limited on the express understanding that it is to be used solely for the purpose f...

Страница 3: ...the heat setting as a percentage of the total power When the temperature probe is fitted the heating is controlled via the temperature feed back circuit and the actual temperature is displayed All ne...

Страница 4: ...estic waste Caution Hot surface Refer to Operator Instruction Manual Stirring Facility On Off Heating Facility On Off Bio Chemical Hazard Caution required Will require decontamination 4 YMBOLS AND USI...

Страница 5: ...ractice Always follow good laboratory practice when using this equipment Give due recognition to your company s safety and legislative health safety procedures and all associated legislation applicabl...

Страница 6: ...perating Practice Always follow good laboratory practice when using this equipment Give due recognition to your company s safety and legislative health safety procedures and all associated legislation...

Страница 7: ...rope 1x Mains lead and moulded IEC plug and lead set USA 1x Mantle 0250ml OR 0500ml OR 1000ml 1x Digi controller with inbuilt stir 4 UNPACK AND CONTENTS 4 1 OMCA0250 OMCA0250X1 OMCA0500 OMCA0500X1 OMC...

Страница 8: ...I Applicable rated pollution degree 2 5 3 This equipment must be earthed grounded to a fixed earth grounded mains socket outlet The mains supply is to be earthed grounded in accordance with current le...

Страница 9: ...issues within the design and manufacturing process without compromising end product performance and value 6 2 Packaging materials have been selected such that they may be sorted for recycling 6 3 At...

Страница 10: ...tion key 3 Heater activation key 4 LCD display 5 Menu selection keys Figure 7 2 6 On off power switch 7 PRODUCT OPERATION 7 1 Overview Your Digi Mantle has been designed for easy operation The illustr...

Страница 11: ...Data communication 17 Read instruction book Figure 8 Typical Front Screen Display Figure 7 4 Figure 7 3 7 External probe socket 8 Date plate label 9 Dry block control plug 10 Dry block power supply so...

Страница 12: ...item 6 to the on position 7 4 2 The LCD display will go through a warm and self check routine that will take a few seconds during which the Digi Mantle Software revision will be displayed for 5 secon...

Страница 13: ...ed selection screen See figure 7 9 Figure 7 9 Press the key to make the 100 s value selection Press the v key if you wish to reduce the selected stir speed value Press the key to go into the 10 s sele...

Страница 14: ...turn to the main display menu To start the heating process press the heating key marked with the symbol To stop the heating process press the heating key once more Note To show heating is in operation...

Страница 15: ...n Heating your sample is now controlled via the external probe From the main display menu screen press the key to go into the Temperature setting screen See figure 7 13 Figure 7 13 Note the Stir tempe...

Страница 16: ...ssue 14 3 7 7 Timer Operation Your Digi Mantle has the facility to set a countdown timer which will switch off the heaters after a per set time period The timer can be set for up to 99hours 59 minutes...

Страница 17: ...the main display screen reverts to t A one second beep is sounded when the heaters are turned off in timer mode Note At any time during the use of the timer facility the heaters may be turned off man...

Страница 18: ...figure 7 29 Figure 7 29 The unit will beep rapidly for 10 seconds The heaters will be turned off If the unit was stirring a sample it will continue to do so The Warning will remain on the LCD until th...

Страница 19: ...in 60 seconds the heaters will be turned off The unit will beep rapidly for 10 seconds If the unit was stirring a sample it will continue to do so The Warning will remain on the LCD until the key is...

Страница 20: ...1000 230V 300W Stir speed Min 100 RPM Max 2000 RPM Fuse rating 115V 7A 32mm x 6 3mm Quickblow 230V 5A 32mm x 6 3mm Quickblow Product configuration details SHM 250D 250 115 115V Controller with stirrer...

Страница 21: ...oller and mantle Weight 3 1kg 21 8 3 Dimensions Weight unpacked Controller Dimension Weight unpacked Controller and Mantle D 330mm W 235mm H190mm Weight 3 1Kg 8 3 Dimensions Weight unpacked Controller...

Страница 22: ...le rating and value See section 8 1 for correct type rating and value and refit into fuse housing See Figure 9 1 Figure 9 1 The equipment is not spark flame or explosion proof and has not been designe...

Страница 23: ...n by pressing button 9 5 Spillage and Decontamination In the event of spillage switch off and unplug this product from the mains electrical supply Wipe off all excess liquid from the unit and surround...

Страница 24: ...X1 1000ml size mantle 300W 115V HH179 S Mains cord and moulded IEC plug and lead set cable UK 10A BS1362 HH180 S Mains cord and moulded IEC plug and lead set cable Europe CRM6288 Mains cord and moulde...

Страница 25: ...r Services at the following address Antylia Scientific Ltd Beacon Road Stone Staffordshire ST15 0SA United Kingdom Tel 44 0 1785 812121 Service cpservice antylia com General enquiries cpinfo antylia c...

Страница 26: ...26...

Страница 27: ...o we cannot guarantee that interference will not occur in practise Where there is a possibility that injury damage or loss might occur if equipment malfunctions due to radio frequency interference or...

Страница 28: ...a T 9122 61394444 E info coleparmer in W coleparmer in China T 1 847 549 7600 E sales antylia com W coleparmer com USA T 1 847 549 7600 E sales antylia com W coleparmer com Canada T 514 355 6100 E inf...

Отзывы: