background image

 

Содержание MTPmini

Страница 1: ......

Страница 2: ...reliable However no responsibility is assumed by Coherent Solutions for its use nor for any infringements of patents or other rights of third parties that may result from its use No license is granted by implication or otherwise under any patent rights of Coherent Solutions The information contained in this publication is subject to change without notice Trademarks Coherent Solutions trademarks ha...

Страница 3: ...reen LCD 13 8 3 2 Changing Numerical Values 14 8 3 3 Changing Numerical Units 14 8 3 4 Changing Step Size 15 8 3 5 Viewing or Changing the Network Settings 15 8 3 6 Orientation Settings 15 8 4 Remote Operation of the MTPmini 16 8 4 1 Web Graphical User Interface 16 8 4 2 Test Instrument Manager Software 16 8 4 3 Programming using Virtual Instrument Software Architecture VISA 16 9 Installing the So...

Страница 4: ...Modular Test Platform MTPmini iii ...

Страница 5: ...ot proceed unless you understand and meet the required conditions CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Do not proceed unless you understand and meet the required conditions CAUTION Indicates a potentially hazardous situation which if not avoided may result in component damage Do not proceed unless you understand and meet th...

Страница 6: ...us situations or impair the protection provided by this unit CAUTION The MTPmini is equipped with fans for thermal regulation Please ensure that there is at least a 15 cm clear space between the sides of the instrument and any surrounding objects IMPORTANT For electromagnetic compatibility this instrument is a Class A product It is intended for use in an industrial environment There may be potenti...

Страница 7: ...nient form factor and customize it to meet your specific requirements Figure 1 Coherent Solutions MTPmini Modular Platform All MTP platforms connected to the network can be managed remotely from a single client using the simple and intuitive Test Instrument Manager software interface Alternatively VISA programming environments such as MATLAB can also be implemented to integrate with existing test ...

Страница 8: ...Pmini V1 4 4 Features MTPmini Front Panel 1 Blade Expansion Slots 2 Bays 2 Touchscreen LCD 3 Thermal Regulation Vents 4 MTPmini Back Panel 4 Mains Power Inlet and Switch 5 Laser Interlock Output Enable Disable Key 6 USB Connection 7 Ethernet Connection ...

Страница 9: ... the ability to connect remotely 2 The Ethernet port of a dedicated client PC this PC being the only client to have remote access using 2a an Ethernet cross over cable 2b Ethernet patch cables and small network hub 5 3 Connecting the USB optional To perform administrative tasks such as configuration of the network settings the USB connection is required You may also require use of the USB as a TCP...

Страница 10: ...the Browse button and locate the oem31 inf file which can be found in the drivers folder within the supplied installation media Click Next to continue 6 Click Continue Anyway when prompted that the driver has not verified its compatibility with Windows 7 If prompted that The file usb8023x sys on Windows driver cabinet is needed click the Browse button and locate the file inside the drivers folder ...

Страница 11: ... module to prevent such damage Take care not to handle the connector on the Blade module once they are exposed as this may leave corrosive residue which can damage the connector Note You will need a Phillips and Slot screwdriver to both unfasten the blanking module and secure the new module in place Power down the MTPmini 1 Press the Power On Off switch to turn the instrument off Figure 3 Turn Off...

Страница 12: ...e MTPmini so it is available to safely store any Blade that may be removed in the future Figure 6 Remove and store Antistatic Packaging Insert the Blade securing into place 5 Slide the Blade into the available slot using the guide rails 6 Once the Blade reaches the connector at the end of the slot press your thumbs on the release latch as shown in Figure 9 to make sure the Blade seats correctly Fi...

Страница 13: ...he Fans will activate to verify that the instrument is powered on Figure 11 Powering On the MTPmini IMPORTANT After powering on the MTPmini please wait at least 1 minutes before attempting to communicate with the instrument This will allow the MTPmini enough time to finish boot procedures and initialize the communication server The new Blade is now ready for use 9 Use your preferred method of comm...

Страница 14: ... blanking modules You will need antistatic packaging to store the Blade upon removal at the appropriate step in the following installation procedures Please make sure this packaging is immediately available before continuing with the following procedure Note You will need a Phillips and Slot screwdriver to both unfasten the Blade module and secure the blanking module in place Acquire storage elect...

Страница 15: ...emove the Blade 4 To remove the desired Blade module loosen the screw underneath the release latch Do not try to remove the screw completely as they are designed to stay inside the release latch Figure 14 Unfasten screw under Release Latch 5 Press downward on the release latch to unseat the Blade module from the back connector as shown in Figure 15 Figure 15 Press down on the Release Latch 6 Slide...

Страница 16: ...lanking module is fully inserted fasten the captive screws on the top and bottom of the blanking module to secure it into place Figure 19 Fasten screws under Release Latch Power on the MTPmini 10 Power on the MTPmini by pressing the Power On Off switch The Fans will activate to verify that the instrument is powered on Figure 20 Power on the MTPmini IMPORTANT After powering on the MTPmini please wa...

Страница 17: ...IMPORTANT After powering on the MTPmini please wait at least 2 minutes before attempting to communicate with the instrument This will allow the MTPmini enough time to finish boot procedures and initialize the communication server To power off the MTPmini press the Power On Off switch The switch will no longer be illuminated to show the instrument is off 8 3 Local Control Touch Screen Graphical Use...

Страница 18: ...s used to set the sign of the input value Numerical values may also be changed by clicking on the and or the and buttons if they appear next to a value The and buttons will use the current step size and unit to determine how much to increase or decrease the value but will not allow the value to exceed the minimum or maximum value The and buttons will increase or decrease from a list of predefined ...

Страница 19: ...anged via the USB interface Figure 25 USB network configuration Figure 26 Ethernet network configuration To allow your network to assign an IP address to the device select the DHCP ON button This will disable IP and SUBNET controls and an IP address will be automatically assigned to the device If DHCP OFF is selected the IP and SUBNET options will be enabled clicking on either of them will show th...

Страница 20: ...wser Simply enter the IP 192 168 100 201 for example if on USB into the address field and you will be taken to the Display menu 8 4 2 Test Instrument Manager Software The Test Instrument Manager software provides an easy to use graphical interface for configuration and management of the installed Blade modules See the corresponding manual for the Blade for details of the use and functionality of t...

Страница 21: ...package 1 When the installation begins you will see the Welcome screen Click on Next to begin the installation 2 Please read the license agreement If you choose to accept the agreement click on the I accept the terms of the License Agreement check box and then click Install If you do not wish to accept the terms of the agreement click on Cancel to terminate the software installation 3 Once the lic...

Страница 22: ...emperature in a clean and dry area Keep the unit out of direct sunlight Avoid high humidity or significant temperature fluctuations Avoid unnecessary shocks and vibrations If any liquids are spilled on or into the unit turn off the power immediately disconnect from any external power source remove the batteries and let the unit dry completely WARNING The use of controls adjustments and procedures ...

Страница 23: ...ubstance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T11363 2006 标准规定的限量 要求 Part Name 部件名称 Toxic or hazardous Substances and Elements 有毒有害物质和元素 Lead 铅 Pb Mercury 汞 Hg Cadmium 镉 Cd Hexavalent Chromium 六价铬 Cr VI Polybrominated biphenyls 多溴联苯 PBB Polybrominated diphenyl ethers 多溴二苯醚 PBDE Enc...

Страница 24: ...ation label as well as a description of your problem close at hand You may also be requested to provide software and module version numbers This information as well as technical support contact information can be found in the About window 11 2 Transportation Maintain a temperature range within specifications when transporting the unit Transportation damage can occur from improper handling The foll...

Страница 25: ...ved The unit has been misused neglected or damaged by accident THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL COHERENT SOLUTIONS BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES 12 2 Liability Coherent Solutions shall not be liable ...

Страница 26: ...upport personnel will determine if the equipment requires service repair or calibration 2 If possible back up your data before sending the unit for repair 3 Pack the equipment in its original shipping material Be sure to supply a statement or report fully detailing the defect and the conditions under which it was observed 4 Return the equipment prepaid to Coherent Solutions Note A test setup fee w...

Страница 27: ...V1 ...