High-Speed Output - Relay/LED Configuration
The Breakout cable can be used to connect the high-speed outputs to a relay, LED or similar load. Connect the negative
side of the load to the output and the positive side to +24VDC. When the output switches on, the negative side of the load
is pulled down to less than 3VDC, and greater than 21VDC appears across the load. Use a protection diode for a large
inductive load, with the anode connected to the output and the cathode connected to +24VDC. For more information,
refer to
.
29
Specifications