Installation
This section describes the connection of the vision system to its standard components and accessories. For a complete
list of options and accessories, contact your Cognex sales representative.
Note
: Cables are sold separately.
CAUTION
:
All cable connectors are “keyed” to fit the connectors on the vision system; do not force the connections
or damage may occur.
Mount the Vision System
Note
:
l
For the mounting holes closest to the lens opening, the thread length of the M3 screw should not exceed
4.5mm. For the mounting holes closest to the connectors, the thread length of the M3 screw should not
exceed 1.6mm. This does not include the thickness of the mounting material used. For more information,
refer to
In-Sight 8200 and 8400 Series Dimensions
and
.
l
The accessory mounting kit includes a mounting block and M3 screws (quantity 4) for mounting the vision
system and securing it to a mounting surface. The mounting block also provides 1/4-20 and M6 mounting
holes for attaching the vision system to a mounting surface. For more information, refer to
8400 Series Dimensions (with Mounting Block)
and
In-Sight 8405 Dimensions (with Mounting
.
l
It is recommended that the vision system be grounded, either by mounting the vision system to a fixture that
is electrically grounded or by attaching a wire from the vision system's mounting fixture to frame ground or
Earth ground.
1. Align the holes on the mounting surface with the mounting holes on the vision system.
2. Insert the M3 screws into the mounting holes and tighten using a 2.5mm hex wrench; the maximum torque is
0.3 Nm (2.5 in-lb).
14
Installation