Specifications
8200
8200C
8400
8400C
8401
8401C
8402
8402C
Voltage
48VDC nominal, applied from a Class 2 PoE device, which is typically powered from some
other voltage.
Material
Die-cast zinc housing.
Finish
Painted.
Mounting
Four M3 threaded mounting holes (1/4-20 and M6 mounting holes also available on
accessory mounting block).
Dimensions
31.0mm (1.22in) x 31.2mm (1.23in) x 75.1mm (2.96in) without accessory mounting block.
39.0mm (1.54in) 31.2mm (1.23in) x 75.1mm (2.96in) with accessory mounting block.
Weight
132.2 g (4.66 oz.) without accessory mounting block.
163.2 g (5.76 oz.) with accessory mounting block.
Case Temperature
1
0°C to 50°C (32°F to 122°F)
Storage Temperature
-20°C to 80°C (-4°F to 176°F)
Humidity
< 80% non-condensing
Protection
IP40 with cables and lens attached.
Shock (Shipping and
Storage)
IEC 60068-2-27: 18 shocks (3 shocks in each polarity in each (X, Y, Z) axis) 80 Gs (800m/s
2
at
11ms, half-sinusoidal)
Vibration (Shipping
and Storage)
IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @ 10 Gs (10 to 500 Hz
at 100m/s
2
/ 15mm)
Regulations/Conformity CE, FCC, KCC, TÜV SÜD NRTL, RoHS
1
Case temperature can be verified using the EV GetSystemConfig(“Internal.Temperature”) Extended Native Mode command. When issued, it
returns the vision system's internal temperature in degrees Celsius, which will be ±5 degrees above the vision system case temperature. Refer
to the
In-Sight
®
Explorer Help
file for more information. Additional cooling measures are required if the case temperature cannot be kept below
50°C. Examples of such measures include: mounting the vision system to a heat sink using the M3 mounting screws, reducing the ambient
temperature and ensuring there is air flow over the vision system.
23