Option 2: Connect the I/O Module Cable
CAUTION
:
A ferrite is included with the In-Sight 8405 vision system standard components. To reduce emissions,
the ferrite must be attached to the I/O Module cable.
Note
:
l
The CIO-MICRO I/O module supports In-Sight 8000 series vision systems with firmware version 5.3.0 and
higher.
l
I/O wiring or adjustments to I/O devices should be performed when the vision system is not receiving power.
1. If installing the In-Sight 8405 vision system, attach the ferrite around the I/O Module cable, adjacent to the strain
relief on the cable.
2. Connect the I/O Module cable’s M8 connector to the vision system’s I/O connector.
3. Connect the I/O Module cable’s DB15 connector to the I/O module’s I/O connector.
4. Restore power to the 24VDC power supply and turn it on if necessary.
17
Installation