High-Speed Output - PNP Configuration
The Breakout cable can be used to connect high-speed outputs with a PNP-compatible PLC input, if a pull-up resistor
(for example, 2.2 kOhms 0.5W) is connected from the output to +24VDC. In this case, the resistor supplies 24VDC to the
PLC input. The output will pull the voltage down to 0VDC, turning off the PLC input. This creates an inversion, with the
PLC input ON when the vision system output is OFF, and vice-versa. Use an external NPN to PNP converter when this
inversion is not desired. For more information, refer to
.
Figure 3-4: High-Speed Output - PNP Configuration
High-Speed Output - Relay/LED Configuration
The Breakout cable can be used to connect the high-speed outputs to a relay, LED or similar load. Connect the negative
side of the load to the output and the positive side to +24VDC. When the output switches on, the negative side of the load
is pulled down to 0VDC, and 24VDC appears across the load. Use a protection diode for a large inductive load, with the
anode connected to the output and the cathode connected to +24VDC. For more information, refer to
Figure 3-5: High-Speed Output - Relay/LED Configuration
20
Содержание In-Sight 5000 Series
Страница 1: ...In Sight 5000 Series Vision System InstallationManual...
Страница 2: ......
Страница 4: ...ii...
Страница 8: ...vi...
Страница 10: ...viii...
Страница 12: ...x...
Страница 20: ...8...
Страница 37: ...Figure 3 7 5100 5100C 5400 5401 5400C and 5403 Vision System Dimensions Without Lens Cover Specifications 25...
Страница 39: ...Figure 3 9 5403S 5400CS and 5400S Vision System Dimensions Without Lens Cover Specifications 27...
Страница 41: ...Figure 3 11 5600 and 5603 Vision System Dimensions Without Lens Cover Specifications 29...
Страница 43: ...Figure 3 13 5604 and 5605 Vision System Dimensions Without Lens Cover Specifications 31...
Страница 44: ...32...
Страница 46: ...34...
Страница 47: ......
Страница 48: ...P N INS 597 0027 07 Rev B...