Note
: When using the vision system with the Breakout cable, the polarity of the and TRIGGER- pins is
not critical. However, when using an optional I/O module, the polarity of the and TRIGGER- pins should
be observed.
Encoder Inputs (In-Sight 5604 Only)
The Breakout cable can be used for communication between the vision system and a single or quadrature encoder. For
single encoders, the ENCODER A pin must be used. For quadrature encoders, the ENCODER A or ENCODER B pin can
be used. The signal from the encoder must be +24VDC. For more information, refer to
Table 3-6: Encoder Input Specifications (In-Sight 5604 only)
Specification
Description
Voltage
ON: 20 to 28VDC (24VDC nominal)
OFF: 0 to 3VDC (9.6VDC nominal threshold)
Current
ON: 84 to 118µA
OFF: < 11µA
Resistance: ~233 kOhms
Maximum Encoder Frequency
99.2KHz (assuming a 50/50 duty cycle)
Figure 3-2: Connect the Encoder
18
Содержание In-Sight 5000 Series
Страница 1: ...In Sight 5000 Series Vision System InstallationManual...
Страница 2: ......
Страница 4: ...ii...
Страница 8: ...vi...
Страница 10: ...viii...
Страница 12: ...x...
Страница 20: ...8...
Страница 37: ...Figure 3 7 5100 5100C 5400 5401 5400C and 5403 Vision System Dimensions Without Lens Cover Specifications 25...
Страница 39: ...Figure 3 9 5403S 5400CS and 5400S Vision System Dimensions Without Lens Cover Specifications 27...
Страница 41: ...Figure 3 11 5600 and 5603 Vision System Dimensions Without Lens Cover Specifications 29...
Страница 43: ...Figure 3 13 5604 and 5605 Vision System Dimensions Without Lens Cover Specifications 31...
Страница 44: ...32...
Страница 46: ...34...
Страница 47: ......
Страница 48: ...P N INS 597 0027 07 Rev B...