40  DataMan 500 Quick Reference Guide

DataMan 500 Quick Reference Guide   41

radio frequency energy and, if not installed and 

used in accordance with the instructions, may 

cause harmful interference to radio communica-

tions. Operation of this equipment in a residential 

area is likely to cause harmful interference, in 

which case the user will be required to correct the 

interference at personal expense.

Canadian Compliance

This Class A digital apparatus complies with 

Canadian ICES-003.

Cet appareil numérique de la classe A est con-

forme à la norme NMB-003 du Canada.

C-Tick Statement

 

 

Conforms to AS/NZS CISPR 22/ EN 55022 for Class 

A Equipment.

European Compliance

 

 

The CE mark on the product indicates that the 

system has been tested to and conforms to 

the provisions noted within the 2004/108/EEC 

Electromagnetic Compatibility Directive and the 

2006/95/EEC Low Voltage Directive. 

For further information please contact:

 

Cognex Corporation

 

One Vision Drive

 

Natick, MA 01760

 USA

Cognex Corporation shall not be liable for use 

of our product with equipment (i.e., power 

supplies, personal computers, etc.) that is not 

CE marked and does not comply with the Low 

Voltage Directive.

Laser Safety Statement

Compliance with FDA performance standards 

for laser products except for deviations 

pursuant to Laser Notice No. 50, dated June 

24, 2007.

This device has been tested in accordance 

with IEC60825-1 2nd ed., and has been certi-

fied to be under the limits of a Class 2 Laser 

device.

Use of controls or adjustments or perfor-

mance of procedures other than those speci-

fied herein may result in hazardous radiation 

exposure.

UL and cUL Statement

 

 

UL and cUL listed: UL60950-1 1st ed. and CSA 

C22.2 No.60950-1 1st ed.

For European Community Users

Cognex complies with Directive 2002/96/EC 

OF THE EUROPEAN PARLIAMENT AND OF THE 

COUNCIL of 27 January 2003 on waste electrical 

and electronic equipment (WEEE).

This product has required the extraction and use 

of natural resources for its production. It may 

contain hazardous substances that could impact 

health and the environment, if not properly 

disposed. 

In order to avoid the dissemination of those sub-

stances in our environment and to diminish the 

pressure on the natural resources, we encourage 

you to use the appropriate take-back systems 

for product disposal. Those systems will reuse or 

recycle most of the materials of the product you 

are disposing in a sound way.

The crossed out wheeled bin symbol informs 

you that the product should not be disposed of 

along with municipal waste and invites you to 

use the appropriate separate take-back systems 

for product disposal.

Compliance Notice 

The DataMan 500 series meets or exceeds the 

requirements of all applicable standards organi-

zations for safe operation. However, as with any 

electrical equipment, the best way to ensure safe 

operation is to operate them according to the 

agency guidelines that follow. Please read these 

guidelines carefully before using your device.

Regulator 

Specification

USA

FCC Part 15, Class A

FDA/CDRH Laser Notice No 50

Canada

ICES-003

European 

Community

EN55022:2006 +A1:2007, Class A
EN55024:1998 +A1:2001 +A2: 

2003

EN60950
EN60825-1

Australia

C-TICK, AS/NZS CISPR 22 / EN 

55022 for Class A Equipment

Japan

J55022, Class A

FCC Class A Compliance Statement

 

This equipment has been tested and found to 

comply with the limits for a Class A digital device, 

pursuant to Part 15 of the FCC rules. These limits 

are designed to provide reasonable protection 

against harmful interference when the equip-

ment is operated in a commercial environment. 

This equipment generates, uses, and can radiate 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание DATAMAN 500

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...COGNEX DataMan 500 Quick Reference Guide san Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisan...

Страница 3: ...ghting Page 30 4 High Power Lighting Module I O Cable Acquisition Triggering High Speed Output Lines High Speed Output Wiring RS 232 Cable 1 Compliance Information Warnings and Notices Page 39 5 DataM...

Страница 4: ...00 Additional information is available through the Windows Start menu after you install the DataMan software on your PC DataMan 500 Reference is a complete online hardware reference for the DataMan 50...

Страница 5: ...0 Accessories CD ROM Setup Tool and Drivers 206 6400 400 Quick Reference Guide 590 7123 Ethernet M12 to RJ45 cable CCB 84901 1003 xx I O Cable M12 to flying leads CCB M12IO S05 RS 232 cables CCB M8X4...

Страница 6: ...rain Use Setup Tool to program additional button functions Green pulse Read Red pulse No read Red Green long pulse Train or Optimize Focus result Yellow Untrained Green Trained Mounting holes M3 X 5mm...

Страница 7: ...reader is unpowered before installing the lens 60 2 36 14 9 0 587 70 0 2 75 161 76 6 37 35 1 38 48 86 1 92 47 1 85 38 1 50 mm inches 46 935 1 85 97 99 3 86 110 38 4 35 27 1 06 Observe the following D...

Страница 8: ...9 N cm 0 8 Lb In 12 DataMan 500 Quick Reference Guide DataMan 500 Quick Reference Guide 13 Installing the Lens continued Replace the supplied liquid lens outer cover with C mount outer cover if requi...

Страница 9: ...Connect the reader to the PoE injector optional To disconnect the reader 1 Disconnect the reader from the PoE injector 2 Disconnect the power cord from the PoE injector 3 Disconnect the PoE injector...

Страница 10: ...eference Guide 17 Reading Distance and Field of View For the DataMan 500 two liquid lens modules are available one with a 13 3 mm lens DM500 LLM 013 and one with a 18 8 mm lens DM500 LLM 018 The follo...

Страница 11: ...0 mil 10 mil 15 mil Reading Distance and Field of View 18 DataMan 500 Quick Reference Guide DataMan 500 Quick Reference Guide 19 Pages 18 19 show the data of a liquid lens with a 40 degree opening ang...

Страница 12: ...ppear in the list of Network devices First check your Ethernet connection with the reader and click Refresh in the Setup Tool Next scan the Enable DHCP code in the Reader Configuration Codes document...

Страница 13: ...stem Settings Configure input and output signals Trigger button Latest image Context based help Read history Train status Connection status Connect the reader to the Setup Tool to configure it with th...

Страница 14: ...formatted The same configuration file can be loaded onto multiple readers as the file does not contain identification information such as the IP address or device name of the reader used to create it...

Страница 15: ...ny symbol it contains or more than one symbol in cases where multicode is enabled The reader relies on an external trigger source Presentation Scans decodes and reports a single code in the field of v...

Страница 16: ...green to indicate that it is currently trained or yellow to indicate that it is not trained Connect the reader to the Setup Tool to untrain it and allow it to recognize other enabled symbologies Incr...

Страница 17: ...Follow the steps in this section to install and remove the module Remove and retain the four mounting screws from the corners of the front cover and remove the cover Use screws removed in Step 2 Obse...

Страница 18: ...evice pin numbering Plug pin numbers are mirrored Acquisition Triggering The acquisition trigger input on the reader is opto isolated To trigger from an NPN pull down type photo detector or PLC output...

Страница 19: ...load Current 50mA maximum sink current OFF state leakage current 100 A External load resistance 240 Ohms to 10K Ohms Each line rated at a maximum 50mA protected against over current short circuits and...

Страница 20: ...r a large inductive load with the anode connected to the output and the cathode connected to 24V To connect to an NPN compatible PLC input connect Output 0 or Output 1 directly to the PLC input When e...

Страница 21: ...64 6 4 and 60068 2 27 RS 232 RxD TxD according to TIA EIA 232 F Codes Data MatrixTM IDMax ECC 0 50 80 100 140 and 200 IDQuick ECC200 QR Code and microQR Code UPC EAN JAN Codabar Interleaved 2 of 5 Cod...

Страница 22: ...ith Directive 2002 96 EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on waste electrical and electronic equipment WEEE This product has required the extraction and use of natural...

Страница 23: ...n hazardous radiation exposure Do not attempt to service or repair this product return it to Cognex for service Do not permit anyone other than Cognex Corporation to service repair or adjust this prod...

Страница 24: ...of the software described in this document may be covered by one or more of the U S patents listed on the Cognex web site http www cognex com patents asp Other U S and foreign patents are pending Cogn...

Страница 25: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: