![Cognex DATAMAN 500 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/cognex/dataman-500/dataman-500_quick-reference-manual_2634681020.webp)
36 DataMan 500 Quick Reference Guide
DataMan 500 Quick Reference Guide 37
High Speed Output Wiring
GND
24VDC
Common
Load
(Coil, Relay...)
Not to exceed
50mA
High Speed Out 0
To connect the high-speed outputs to a relay, LED or similar load,
connect the negative side of the load to the output and the positive side
to +24V. When the output switches on, the negative side of the load
is pulled down to less than 3V, and 24 appears across the load. Use a
protection diode for a large inductive load, with the anode connected to
the output and the cathode connected to +24V.
To connect to an NPN-compatible PLC input, connect Output 0 or Output 1
directly to the PLC input. When enabled, the output pulls the PLC input down to
less than 3V.
GND
24VDC
Common
High Speed Out 0
NPN PLC
NPN Compatible Input
GND
24VDC
To connect to a PNP-compatible PLC input, connect Output 0 or Output 1
directly to the PLC input. When enabled, the output pulls the PLC input up to
greater than 21V.
GND
24VDC
Common
High Speed Out 0
PNP PLC
PNP Compatible Input
GND
24VDC
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com