17
.
6. Cleaning program
CLEANING:
Royal
Automatic cleaning of In/Outlet valves:
The In/Outlet valves can easily be cleaned with the key switch in ”cup” (normal) position.
1.
Place a jug in the drip tray.
2.
Turn the key slowly ninety degrees and back again.
3.
Push button for drink 1 and 2 at the same time for
6 seconds.
Keep buttons down.
All In/Outlet valves will now start to open and close
with 2 pulses/second in 10 seconds or as long as you
hold the buttons.
The display shows: ”Cleaning valves”.
4.
Push button for drink 2 for making a brew
cycle and flush remaining water and scale from the
cleaning.
2.
4
3
3