background image

  

4. Installation.

Queen Aqua Table Top

WATER LINE

8.

Queen Aqua Table Top Installation

4

.

Mount the gas dome (A) on the carbon dioxide
bottle (B) and then fit the nipple supplied for the
water hose on the gas dome.

5

.

Mount using the elbow connections supplied under
the chiller unit 1 and 2.

6

.

Connect the hose from the carbon dioxide tube to
the cooling unit’s elbow connection. See 1.
(Carbonated water).

7

.

Mount the water filter with regulator (C) and connect
the hose from the water filter to the chiller unit’s
elbow connection. See 2. (cold water).

8

.

Connect the ½” hose to the water filter and then to
the mains water supply (D).

The most appropriate connection is to a tap that
can be turned off.

(Check to ensure that no kinks or sharp bends are
formed on the hoses during connection.)

9

.

Insert the power plug in an 

earthed wall socket.

10

.

Flush out approximately 2.5 litres chilled water and
then approximately 2.5 litres carbonated water
before the machine is taken into use.

A

B

C

The installation shall be performed by an authorised installer.

Water filter
with regulator

D

Water IN

(When installing hoses that go straight down, two holes need to be drilled

for the incoming hoses. See fig.(A).

Fig. A

Содержание COFFEE

Страница 1: ...U_EN Rev 090914 Your retailer Serves chilled water and chilled carbonated water COFFEE QUEEN QUEEN AQUA Table Top QUEEN AQUA Floor model User manual ...

Страница 2: ...WATER LINE 1 Contents 2 2 Notes for the user 3 3 Using the machine 4 4 QueenAqua Installation 5 6 4 Installation QueenAqua table top 7 8 5 Care replacing a water filter 9 6 Cleaning the machine 10 7 Important 11 2 ...

Страница 3: ...he perfect temperature You can choose whether you want chilled water or carbonated water You can also choose whether you want water in a glass jug or bottle 3 Product identification Queen Aqua Queen Aqua table top Height 1355 470 Width 310 210 Depth 330 330 Electrical connection 230 V 10 A 230 V 10 A Cold water connection 1 2 1 2 Refrigerant HFC 134A HFC 134A Cooling capacity 17 litres per hour 17...

Страница 4: ...s below the outlet for the required drink Press one of the buttons Water will continue to run as long as you keep the button pressed Outlet for chilled drinks QueenAqua has two outlets for chilled drinks Outlet carbonated water Outlet cold water ...

Страница 5: ...e connection s body as far as possible Disconnecting the John Guest connection Push the grey ring towards the connection and pull out the hose If the water hoses need to be cut make a straight cut to prevent leakage Queen Aqua Installation 1 Place the machine on a level and waterproof surface 2 Mount the machine on the floor cabinet and screw in place using the screws supplied Use a spirit level w...

Страница 6: ...it See 2 Cold water 7 Connect the hose supplied to the machine E and then to the mains water supply The most appropriate connection is to a tap that can be turned off Check to ensure that no kinks or sharp bends are formed on the hoses during connection Water IN 8 Insert the plug in an earthed 230 V 10 A wall socket 9 Flush out approximately 2 5 litres chilled water and then approximately 2 5 litr...

Страница 7: ... must be disconnected from the mains when work is done on it Pull the power supply cable out of the wall socket It is the end customer s user s responsibility to arrange the water connection to the machine according to the manufacturer s instructions NOTE WORKING WITH THE CONNECTIONS Hold the connection and press the hose into the connection s body as far as possible Disconnecting the John Guest c...

Страница 8: ...iller unit s elbow connection See 2 cold water 8 Connect the hose to the water filter and then to the mains water supply D The most appropriate connection is to a tap that can be turned off Check to ensure that no kinks or sharp bends are formed on the hoses during connection 9 Insert the power plug in an earthed wall socket 10 Flush out approximately 2 5 litres chilled water and then approximatel...

Страница 9: ...1 OPEN 2 Assemble the new filter by turn it 1 4 lap See fig 1 CLOSE To make sure a high quality on drinks replace water cleaning filter every 6 months Fig 1 water filter 3 IMPORTANT Now push the button for cold water Push until water is coming out in a regularly flow Only use Coffee Queen original water cleaning filter Article no 1505344 Filter from below ...

Страница 10: ...6 Cleaning Daily cleaning WATER LINE 10 Outside cleaning use asoft rag and liquid cleaning agent to prevent scratches Daily cleaning or when needed Empty and clean drip tray and drip tray insert daily ...

Страница 11: ...on it This can be done by pulling out the plug from the wall socket CHILLER SYSTEM INSTALLATION AND LOCATION The system is designed for use in standard environments according to CCN standard 33 2000 3 and is included in climate class N It must not be located close to a heat source or be subjected to direct sunlight The system is designed for use in an ambient temperature of no lower than 6 C and n...

Страница 12: ...rt nr Art no 1730009 FOR SERVICE please contact CREM International AB Box 960 671 29 ARVIKA Sweden Tel 46 0 570 477 00 Fax 46 0 570 47719 E mail info se creminternational com www creminternational com Your retailer ...