Important

Do not do anything to the water dispenser. Inappropriate action can lead to personal injury and
faults.

The water dispenser should stand on a level surface to work satisfactorily.
The water dispenser must be placed on a waterproof surface so that any water leakage is visible.

Make sure that kinks are not formed in the connection hose during installation or when the water
dispenser is pushed into place. The machine’s supply and drain connection shall be checked
regularly. Check that no leakage has occurred in connection with installation.

The water connection always presents a risk of leakage irrespective of safety equipment.
The water dispenser must be completely drained of water if it is going to be stored for a long time.

Turn off the water tap if the machine is not going to be used for a long time.
Disconnect the machine from the electricity supply before doing any work on it.

This can be done by pulling out the plug from the wall socket.

CHILLER SYSTEM

INSTALLATION AND LOCATION:

The system is designed for use in standard environments according to CCN standard 33 2000-3
and is included in climate class N.

It must not be located close to a heat source or be subjected to direct sunlight.

The system is designed for use in an ambient temperature of no lower than 6°C and no higher
than 28°C.

The system must not be used or placed in an ambient temperature that is lower than 0

o

C.

ELECTRICAL CONNECTION

Connect the system to 220–240 V, 50 Hz and 10 A. The contact for electrical installation shall
comply with the current CSN regulations, EN and ISO standards. If the cable is damaged, it
must be replaced by a qualified person. This is to prevent an accident.

CONNECTION AND SERVICE:

The condenser shall be cleaned every 6 months in connection with water filter replacement.

Use compressed air when cleaning.
Carry out cleaning only once the power supply is disconnected from the chiller!

All installation work must be done by a qualified person.

 

 

7. Important.

WATER LINE

11.

Содержание COFFEE

Страница 1: ...U_EN Rev 090914 Your retailer Serves chilled water and chilled carbonated water COFFEE QUEEN QUEEN AQUA Table Top QUEEN AQUA Floor model User manual ...

Страница 2: ...WATER LINE 1 Contents 2 2 Notes for the user 3 3 Using the machine 4 4 QueenAqua Installation 5 6 4 Installation QueenAqua table top 7 8 5 Care replacing a water filter 9 6 Cleaning the machine 10 7 Important 11 2 ...

Страница 3: ...he perfect temperature You can choose whether you want chilled water or carbonated water You can also choose whether you want water in a glass jug or bottle 3 Product identification Queen Aqua Queen Aqua table top Height 1355 470 Width 310 210 Depth 330 330 Electrical connection 230 V 10 A 230 V 10 A Cold water connection 1 2 1 2 Refrigerant HFC 134A HFC 134A Cooling capacity 17 litres per hour 17...

Страница 4: ...s below the outlet for the required drink Press one of the buttons Water will continue to run as long as you keep the button pressed Outlet for chilled drinks QueenAqua has two outlets for chilled drinks Outlet carbonated water Outlet cold water ...

Страница 5: ...e connection s body as far as possible Disconnecting the John Guest connection Push the grey ring towards the connection and pull out the hose If the water hoses need to be cut make a straight cut to prevent leakage Queen Aqua Installation 1 Place the machine on a level and waterproof surface 2 Mount the machine on the floor cabinet and screw in place using the screws supplied Use a spirit level w...

Страница 6: ...it See 2 Cold water 7 Connect the hose supplied to the machine E and then to the mains water supply The most appropriate connection is to a tap that can be turned off Check to ensure that no kinks or sharp bends are formed on the hoses during connection Water IN 8 Insert the plug in an earthed 230 V 10 A wall socket 9 Flush out approximately 2 5 litres chilled water and then approximately 2 5 litr...

Страница 7: ... must be disconnected from the mains when work is done on it Pull the power supply cable out of the wall socket It is the end customer s user s responsibility to arrange the water connection to the machine according to the manufacturer s instructions NOTE WORKING WITH THE CONNECTIONS Hold the connection and press the hose into the connection s body as far as possible Disconnecting the John Guest c...

Страница 8: ...iller unit s elbow connection See 2 cold water 8 Connect the hose to the water filter and then to the mains water supply D The most appropriate connection is to a tap that can be turned off Check to ensure that no kinks or sharp bends are formed on the hoses during connection 9 Insert the power plug in an earthed wall socket 10 Flush out approximately 2 5 litres chilled water and then approximatel...

Страница 9: ...1 OPEN 2 Assemble the new filter by turn it 1 4 lap See fig 1 CLOSE To make sure a high quality on drinks replace water cleaning filter every 6 months Fig 1 water filter 3 IMPORTANT Now push the button for cold water Push until water is coming out in a regularly flow Only use Coffee Queen original water cleaning filter Article no 1505344 Filter from below ...

Страница 10: ...6 Cleaning Daily cleaning WATER LINE 10 Outside cleaning use asoft rag and liquid cleaning agent to prevent scratches Daily cleaning or when needed Empty and clean drip tray and drip tray insert daily ...

Страница 11: ...on it This can be done by pulling out the plug from the wall socket CHILLER SYSTEM INSTALLATION AND LOCATION The system is designed for use in standard environments according to CCN standard 33 2000 3 and is included in climate class N It must not be located close to a heat source or be subjected to direct sunlight The system is designed for use in an ambient temperature of no lower than 6 C and n...

Страница 12: ...rt nr Art no 1730009 FOR SERVICE please contact CREM International AB Box 960 671 29 ARVIKA Sweden Tel 46 0 570 477 00 Fax 46 0 570 47719 E mail info se creminternational com www creminternational com Your retailer ...

Отзывы: