Operation manual SR25
February 2017
Page 28
Coffed BDH | ul. Ceramiczna 28 | 64-
920 Piła PL | tel+48 67 214 26 29 | www.coffed.pl
- reset the message after the fault or error has been removed
- go to the previous message
- go to the next message
Code
Message
Solution
F00
Emergency stop!
Check the emergency switch. Press
the safety ciruct reset button
F01
Drum not rotating!
Check the 4M1 motor.
F02
Temperature too high! Check monitoring relays.
Check the 10A1 relay.
In the event of the surpassing the
exhaust fumes temperature, the relay
needs to be reset by the indicated
button
F03
Cooling bin/stirflex stop switch active!
Check the emergency switch on the
cooling bin.
F04
External stop active!
Check the external applances
F05
Burner failure!
Check the 11F1 fuse.
F06
Air pressure to low!
Check the air pressure.
F07
Stirlflex emergency stop!
Check the stirflex emergency stop on
the control panel.
F10
Temepature coffee or exhaust too high!
Check the temperature monitoring
relays.
F11
Destoner blower fault!
Check the 7U1 inverter and the 7F1
fuse.
F12
Exhaust blower failure!
Check the 5U1 inverter and the 5F1
fuse.
F13
Cooling motor failure!
Check the 8Q1 fuse.
F14
Main motor failure!
Check the 4U1 inverter and the 4F1
fuse.
F15
Agitator motor failure!
Check the 6U1 inverter and the 6F1
fuse.
F16
Inlet blower failure!
Check the 8Q2 fuse.
F21
Inlet flap failure!
Check the inlet flap actuator position.