This function allows for the transmission of bidirectional data with the
DR1
(cod.
CO9703
). Via the
DR1
(display remote) it is possible
to remotely access, view and alter all the fixture’s parameters and settings.
The
DR1
remote display unit allows the user to:
Monitor:
1) the current Software Version loaded
2) led operating life
3) projector operating life
4) presence and characteristics of incoming DMX 512
5) error messages
6) ID code
7) alarms
Edit and set:
1) DMX address
2) function mode
Execute:
1) Function test
2) Software update
3) Color alignment
To initiate communications with the
Strip Lite Led RGB
the
DR1
must be installed into the DMX signal chain between the fixture
and the controller following the instructions located internally on the unit.
The
DR1
dip-switch must be set to the
ON position
; from this point on, dip-switches 1 to 128 take on the task of assigning an iden-
tifying value (ID) to the fixture. They no longer set the fixture’s DMX address, which is done by the
DR1
. The maximum number of
unique IDs available in the
DR1
system is 250; dip-switch 256 has no functionality.
An example of a possible configuration is shown below:
Strip Lite Led RGB
set to ID 13 and
DR1 active
configured by setting dip-switch
DR1
to
ON
and dip-switches
1, 4
and
8
to
ON
ON
256
auto
test
light on
DR1
1
2
4
8 16 32 64 128
ATTENTION!!
All the function in this chapter are exclusively activateable from DR1.
11. DR1 function
18
English