3) Locate the safety clip (E) which can be used to attach the lid to any appropriate
component which can support its weight, for example the yoke of the projector (F).
4) Locate the SFc 15,5 lampbase (C).
4) The SFc 15,5 lampbase is symmetrical; the lamp is quartz glass and must be hand-
led with care; follow the instructions included in the lamp’s packaging. Do not
touch the glass directly, use the tissue provided in the box.
Loosen the two nuts located on the lamp (D).
Insert the lamp into the lampholder (C). If you encounter difficulty during this ope-
ration, DO NO USE UNDUE FORCE. Re-read the instructions and repeat the pro-
cedure.
To ensure a uniform beam spread, rotate the lamp in its lampholder so that the
protruding pinch of glass in the centre of the lamp is pointing downwards within
the fixture.
Press the ends of the lamp down into the lampbase. If this procedure is not fol-
lowed correctly, the beam spread may not be uniform.
5) Tighten the two nuts located on the lamp (D).
6) Replace the inspection lid (B) into its guides sliding it firmly forwards to ensure it is
correctly seated.
Replace and tighten the screws (A).
B
A
D
C
E
F