5. Load connection
DIGIfactor
club
6x2,5Kw
can control a maximum of 6 channels @ 2,5 Kw; with a maximum of 10 Amps per channel.
Do not overload the outlets!
Refer to local regualtions and norms with respect to the correct cabling required for connection of loads to dimmers in
public locations.
A good and secure earth connection is essential.
1) Loosen the four screw (A) on the rear panel (B) of the
DIGIfactor
club
6x2,5Kw
; using a cable of suitable rating slide it
through the cable clamp (C) located on the rear of the unit and secure it firmly.
2) Connect the load cables, referring to the schematic shown, where a standard load is indicated by lamps.
3) Re-close the rear of the
DIGIfactor
club
6x2,5Kw
.
GND
Terra
Load/Carico
ch5
n
ch6
n
5
n
6
n
Load/Carico
ch3
n
ch4
n
3
n
4
n
Load/Carico
ch1
n
ch2
n
1
n
2
n
A
made in italy - Castel Goffredo (MN)
serial number
ATTENZIONE!
Alta tensione all'interno dell'apparecchio - Togliere tensione prima di rimuovere il pannello
Questa apparecchiatura deve essere installata esclusivamente da persone competenti,
seguendo scrupolosamente il manuale d'installazione fornito dalla ditta e le vigenti
normative. Una buona connessione di terra è essenziale
Contenitore caldo - 50
°
C in funzionamento normale, non installare su superficie
infiammabile Massima temperatura ambiente: 40
°
C
WARNING!
High voltage inside - Disconnect from supply before removing cover
This unit must be installed by a competent person in accordance
with the manufacturer's instructions and the safety norms.
A good earth connection is essential
Hot Case - 50
°
C normal operation, Do not install on flammable surfaces.
Max ambience temperature: 40
°
C
B
Svitate le 4 viti per accedere alla connessione di potenza / Untighten 4 screws to access power terminal blocks
Caratteristiche di alimentazione:
Tensione: 200 - 260v AC trifase, collegamento
a stella (R S T +N + ) o triangolo
Frequenza: 50/60 Hz autoregolante
Assorbimento di corrente massimo: 20 A per fase
Carico massimo per canale: 10 A
Mains supply requirements:
Voltage:210 - 250v AC 3 phase, star
(R S T + N + ) or delta
Frequency: 50/60 Hz autosensing
Current requirement: 20 Amps per phase Max
Maximum load per channel: 10 Amps
C
C