8. DMX addressing or analogue 0/+10v DC
As described in section 6 you may use the
DIGIfactor
club
6x2,5Kw
with either 0/+10V DC or DMX 512 control signals;
depending upon the requirements of your controller
8.1 0/10 v DC
After having correctly connected the cable, channel number 1 of the
DIGIfactor
club
6x2,5Kw
corresponds to the signal
being sent via pin 1 of the Locking DIN; channel number 2 corresponds to the signal being sent via pin 2 of the Locking
DIN, and so on until the 6th channel being via pin number 6 of the Locking DIN.
A variation in the voltage from 0 to 10 V of the control signal corresponds to a variation of the load voltage from 0 to 230 V.
8.2 DMX 512
After correct connection of the DMX 512 signal cable, the 6 channels of the dimmer are controlled via 6 channels of your
DMX controller in sequence.
Upon first turning on the dimmer’s display shows
A001
indicating the address
DMX 1
.
A dimmer so addressed will respond to channels
1
through
6
of the
DMX 512
controller, a second dimmer should be
addressed as
7
, and so on in multiples of 6.
A dimmer can therefore respond to whichever 6 sequential channels of the controller you wish simply by changing the
display’s address.
Note that after the first address is set,
DIGIfactor
club
6x2,5Kw
will also occupy the next 5 addresses as well.
changing the dmx address
Important Note
: Keeping the
+
or
-
buttons depressed will cause the display to scroll at high speed, allowing for rapid
chaing ing .
The presence of DMX signal is indicated by the flashing led in the DMX input display.
dmx
input display
function display
PConfirms your selection of address, the display
stops flashing and the unit responds to the new
DMX 512
address.
function display
Press the
enter
button
Shows the
DMX
addresses from 1 to 501, the led
display will flash, indicating that the change has
not been recorded yet, for example, 7
function display
Press the
+
or
-
buttons until the desired channel
is shown
Address
DMX 001
Power up the
DIGIfactor
club
6x2,5Kw