9.3.4. Switching channel pre-heating
Causes sufficient voltage to be applied to the channel’s load to assist in preventing lamp/transformer failure due to large
thermal differences between fixture on and off states.You may select this function only if the channels have been set to swit-
ching
ScH1
as described above.
Pv00
pre-heat at level
0
function display
Press the
enter
button
For example, channel
6
previously set to
ScH1
function display
Press the
+
or
-
button until the required channel
is selected
To confirm your selection
Press the
enter
button
Lamp pre-heating
function display
Press the
+
or
-
button until
PrEH
is displayed
To confirm your selection
Press the
enter
button
Function menu displayed
function display
Simultaneously press the
menu
and
enter
but-
tons
DIGIfactor
club
6x2,5Kw
turns on
Power up
DIGIfactor
club
6x2,5Kw
To confirm your selection
Press the
enter
button
Transformer switching function (allows pre-heat to
be assigned)
function display
Press the
+
or
-
button until
ScH1
is displayed
Switching standard function
function display
Press the
+
or
-
button until
ScH0
is displayed
Dimmer function
function display
Press the
+
or
-
button until
cdiM
is displayed
To confirm your selection
Press the
enter
button
For example, channel
1
function display
Press the
+
or
-
buttons until the required channel
is selected.
To confirm your selection
Press the
enter
button