S
ervice
29
WATER PUMP
The water pump distributes the water & silicone solution to the
water manifolds on the shaker head.
DIAPHRAGM CHECK
The diaphragm check prevents water from back feeding
during suction phase of water system cycle. If cap becomes loose the rubber dia-
phragm may be injected into one of the water delivery lines. Loosen diaphragm when
priming water system, tighten when water flow occurs. Refer to trouble shooting sec-
tion to assist in resolution of water system issues.
PRESSURE TRANSDUCER
The pressure transducer monitors the water system
pressure. If no pressure is sensed then a warning is flashed on the screen.
FILTER
SCREENER
The filter / screener prevents contaminants from being introduced
into the water system & components to prevent clogging.
Water system