background image

Page 6 of 12

Fusing Instructions (Independent Flashing Units):

LED  Fusing Considerations

Although the average current draw per module is very low, due to the type of circuit used to power each module, the instantaneous peak 

current to a module can be significantly higher during low voltage conditions. To avoid prematurely blowing ATO style fuses or tripping 

breakers it is recommended the following rule-of-thumb be used to size fuses or breakers. This is especially important in lightbars with many 

LED modules running off a single fused source.

Minimum fuse size calculation: 20A

For LED 12 volt electrical current

1.5  X (number of 4, 6, & 9LED modules being fused) = Total Electrical Current at 12.8 VDC or

0.5  X (number of 3LED modules being fused)             = Total Electrical Current at 12.8 VDC

LED MODULES

Operating Specifications for directional module:

 

 

Operating Voltage: 10-16 VDC, Reverse Polarity Protection

 

    

Current  Draw : Flashing Module

 

 

 

 

Red/Amber -  .25A avg @ 12.8 Volts

 

 

 

 

Blue/White    -  .4A avg @ 12.8 Volts

    

    Steady 

Burn 

Module

 

 

 

 

Red/Amber -  .5A avg @ 12.8 Volts

 

 

 

 

Blue/White     -  .8A avg @ 12.8 Volts

  

 

 

Available Colors - Red , Blue, Amber, and White

Fash Pattern Instructions (Independent Flashing Units):

CAUTION!

This product contains high intensity LED devices.  To prevent eye damage, DO NOT stare into the light beam at close range.

INSTALLER NOTE:

FLASH RATE + FLASH SEQUENCE = FLASH PATTERN

Lighthead Flash Sequences - Multi Color

LEFT / RIGHT

(DEFAULT):

PRIMARY & SECONDARY

PRIMARY ONLY - 

LEVEL - 1 DEFAULT

SECONDARY ONLY

PRIMARY W / SECONDARY POPS

PRIMARY W / SECONDARY RANDOM

EVEN / ODD:

PRIMARY & SECONDARY

PRIMARY ONLY - 

LEVEL - 2 DEFAULT

SECONDARY ONLY

PRIMARY W / SECONDARY POPS

PRIMARY W / SECONDARY RANDOM

RANDOM:

PRIMARY & SECONDARY

PRIMARY ONLY

SECONDARY ONLY

PRIMARY W / SECONDARY POPS

PRIMARY W / SECONDARY RANDOM

CYCLE SEQUENCE

RANDOM:

PRIMARY & SECONDARY

PRIMARY ONLY

SECONDARY ONLY

PRIMARY W / SECONDARY POPS

PRIMARY W / SECONDARY RANDOM

ALL ON

RANDOM:

PRIMARY & SECONDARY

SWEEP

LEFT / RIGHT:

SECONDARY ONLY

NULL:

ALL LIGHTHEADS OFF

Lighthead Flash Sequences - Multi Color

Double Flash-75 

LEVEL - 2 DEFAULT

Triple Flash-75
Quad Flash-75
Quint Flash-75
Double Flash-150
Triple Flash-150 

LEVEL - 1 DEFAULT

Quad Flash-150
Quint Flash-150
Triple Pop Flash-150
Quad Pop Flash-150
Single Flash-375
Cycle Rates

Содержание WingMan Flex Series

Страница 1: ...y In use the vehicle operator should ensure the projection of the warning signal is not blocked by vehicle components i e open trunks or compartment doors people vehicles or other obstructions 6 The u...

Страница 2: ...stantial air gap between them In some cases you will need to self fabricate brackets to adapt the WingMan Flex to your vehicle Caution When installing the unit do not push it too hard against the rear...

Страница 3: ...t breakers are very sensitive to high temperatures and will false trip when mounted in hot environments or operated close to their capacity It is advisable to leave an extra loop of cable when install...

Страница 4: ...T RED WHITE WHITE ORANGE GREEN WHITE LIGHT BLUE BLANK BRACKET ALL COLORED WIRES BELOW CONNECT TO 12VDC BLACK WIRE CONNECTS TO GROUND DO NOT CONNECT UNUSED WIRES TO POWER WIRING DIAGRAM 6 LIGHT HEAD SI...

Страница 5: ...CONNECT TO BACK SIDE OF NARROWSTIK CONTROL HEAD 12VDC CONTROL HEAD POWER COLORED WIRES CONNECT TO THEIR MATCHING COLOR LOCATIONS IN PLUG IN BACK SIDE OF NARROWSTIK CONTROL HD INTERNAL WIRING DIAGRAM 8...

Страница 6: ...mber 5A avg 12 8 Volts Blue White 8A avg 12 8 Volts Available Colors Red Blue Amber and White Fash Pattern Instructions Independent Flashing Units CAUTION This product contains high intensity LED devi...

Страница 7: ...lly replace the cover and fasten cover mounting screws Note Be extremely careful to replace the wiring such that you don t pinch a wire when you replace the cover Test the unit to be sure that it work...

Страница 8: ...formation on repair and troubleshooting Additional information may be obtained from the factory technical help line at 314 996 2800 Note LED modules must be replaced as a module There are no user serv...

Страница 9: ...Version 220 0681 00 1 2M Chassis MINI Version 220 0680 00 1 3 18LED Multi Color Light Head Module Contact Code 3 Inc for P N Up to 8 4 9LED Single Color Light Head Module Contact Code 3 Inc for P N U...

Страница 10: ...Page 10 of 12 Notes...

Страница 11: ...Page 11 of 12 Notes...

Страница 12: ...TIES FOR MERCHANTABILITY QUALITY OR FITNESS FOR A PARTICULAR PURPOSE OR ARISING FROM A COURSE OF DEALING USAGE OR TRADE PRACTICE ARE HEREBY EX CLUDED AND SHALL NOT APPLY TO THE PRODUCT AND ARE HEREBY...

Отзывы: