Notes:

1.  Larger wires and tight connections will provide longer service life for components. For high current wires it is highly recommended 

that terminal blocks or soldered connections be used with shrink tubing to protect the connections. Do not use insulation displacement 

connectors (e.g., 3M Scotchlock type connectors).

2.  Route wiring using grommets and sealant when passing through compartment walls. Minimize the number of splices to reduce voltage 

drop. All wiring should conform to the minimum wire size and other recommendations of the manufacturer and be protected from moving 

parts and hot surfaces. Looms, grommets, cable ties, and similar installation hardware should be used to anchor and protect all wiring.

3. 

Fuses or circuit breakers should be located as close to the power takeoff points as possible and properly sized to protect the wiring and 

devices.

4.  Particular attention should be paid to the location and method of making electrical connections and splices to protect these points from 

corrosion and loss of conductivity.

5.  Ground termination should only be made to substantial chassis components, preferably directly to the vehicle battery.

6.  Circuit breakers are very sensitive to high temperatures and will “false trip” when mounted in hot environments or operated close to their 

capacity.

It is advisable to leave an extra loop of cable when installing the light bar to allow for future changes or reinstallations.Connect the wires in 

the cable for the WingMan Flex Version you are installing as shown in the following diagrams.

Wiring Instructions:

IMPORTANT! This unit is a safety device and it must be connected to its own separate, fused power point to assure its continued operation 

should any other electrical accessory fail.

All Multi Color, Single Color & Multi Color / Single Color Combinations, excluding MINI Single Color Version:

                                                                                                                              FLASH PATTERN CONTROL WIRES

                     POWER/GROUND                                                 CONNECT WIRES TO +12VDC TO PERFORM FUNCTIONS LISTED

RED WIRE----------------------- POWER +12VDC                                           GREEN WIRE------------------- ARROWSTIK RIGHT  

PROTECT WITH 20 AMP FUSE                                                                   

                                                                                                                      WHITE WIRE---------------------- ARROWSTIK LEFT

BLACK WIRE------------------- GROUND WIRE   

                                                                                                                      GREEN + WHITE------ ARROWSTIK CENTER OUT                                                                                                                          

                                          

                                                                                                                      PURPLE WIRE------------------ ARROWSTIK FLASH

                                                                                                                      LIGHT BLUE  WIRE-----------  SCENE LIGHTS

                                                                                                                      BLUE WIRE---------------------- DIMMING

                                                                                                                      YELLOW / BLACK WIRE --- SEQUENCE SELECT  

                                                                                                                      YELLOW WIRE----------------- RATE SELECT

                                                                                                                      BROWN WIRE------------------ LEVEL 1 FLASH

                                                                                                                      ORANGE WIRE----------------- LEVEL 2 FLASH

LONG 

VERSION

LIGHT BAR CABLE

SHORT 

VERSION

MINI 

VERSION

WINGMAN FLEX WIRING

MULTI COLOR, SINGLE COLOR & MULTI COLOR / SINGLE COLOR 

COMBINATIONS ALL VERSIONS EXCEPT MINI SINGLE COLOR VERSION

FOR MINI SINGLE COLOR VERSION SEE TOP OF PAGE 17

SEE FUSING RECOMMENDATION

Содержание WingMan Flex Series

Страница 1: ...y In use the vehicle operator should ensure the projection of the warning signal is not blocked by vehicle components i e open trunks or compartment doors people vehicles or other obstructions 6 The u...

Страница 2: ...stantial air gap between them In some cases you will need to self fabricate brackets to adapt the WingMan Flex to your vehicle Caution When installing the unit do not push it too hard against the rear...

Страница 3: ...t breakers are very sensitive to high temperatures and will false trip when mounted in hot environments or operated close to their capacity It is advisable to leave an extra loop of cable when install...

Страница 4: ...T RED WHITE WHITE ORANGE GREEN WHITE LIGHT BLUE BLANK BRACKET ALL COLORED WIRES BELOW CONNECT TO 12VDC BLACK WIRE CONNECTS TO GROUND DO NOT CONNECT UNUSED WIRES TO POWER WIRING DIAGRAM 6 LIGHT HEAD SI...

Страница 5: ...CONNECT TO BACK SIDE OF NARROWSTIK CONTROL HEAD 12VDC CONTROL HEAD POWER COLORED WIRES CONNECT TO THEIR MATCHING COLOR LOCATIONS IN PLUG IN BACK SIDE OF NARROWSTIK CONTROL HD INTERNAL WIRING DIAGRAM 8...

Страница 6: ...mber 5A avg 12 8 Volts Blue White 8A avg 12 8 Volts Available Colors Red Blue Amber and White Fash Pattern Instructions Independent Flashing Units CAUTION This product contains high intensity LED devi...

Страница 7: ...lly replace the cover and fasten cover mounting screws Note Be extremely careful to replace the wiring such that you don t pinch a wire when you replace the cover Test the unit to be sure that it work...

Страница 8: ...formation on repair and troubleshooting Additional information may be obtained from the factory technical help line at 314 996 2800 Note LED modules must be replaced as a module There are no user serv...

Страница 9: ...Version 220 0681 00 1 2M Chassis MINI Version 220 0680 00 1 3 18LED Multi Color Light Head Module Contact Code 3 Inc for P N Up to 8 4 9LED Single Color Light Head Module Contact Code 3 Inc for P N U...

Страница 10: ...Page 10 of 12 Notes...

Страница 11: ...Page 11 of 12 Notes...

Страница 12: ...TIES FOR MERCHANTABILITY QUALITY OR FITNESS FOR A PARTICULAR PURPOSE OR ARISING FROM A COURSE OF DEALING USAGE OR TRADE PRACTICE ARE HEREBY EX CLUDED AND SHALL NOT APPLY TO THE PRODUCT AND ARE HEREBY...

Отзывы: