background image

Revision 0, 09/09 - Instruction Book Part No. T16417

©2009 Public Safety Equipment, Inc. Printed in USA

PRODUCT RETURNS

If a product must be returned for repair or replacement*, please contact our factory to obtain a Return 

Goods Authorization Number  (RGA number) before you ship the product to Code 3, Inc.  Write the RGA number 
clearly on the package near the mailing label.  Be sure you use suffi cient packing materials to avoid damage to 
the product being returned while in transit.

*Code 3, Inc. reserves the right to repair or replace at its discretion.  Code 3, Inc. assumes no responsibility or liability for expenses incurred for the removal and /or 

reinstallation of products requiring service and/or repair.; nor for the packaging, handling, and shipping: nor for the handling of products return to sender after the service has been 
rendered.

Code 3, Inc.

10986 N. Warson Road

St. Louis, Missouri 63114-2029—USA

Ph. (314) 426-2700  Fax (314) 426-1337

www.code3pse.com

WARRANTY

Code 3, Inc.'s L.E.D. emergency devices are tested and found to be operational at the time of manufacture.  

Provided they are installed and operated in accordance with manufacturer's recommendations, Code 3, Inc. guarantees 
all parts and components except the lamps to a period of 1 year, LED Lighthead modules to a period of 5 years (unless 
otherwise expressed) from the date of purchase or delivery, whichever is later.  Units demonstrated to be defective 
within the warranty period will be repaired or replaced at the factory service center at no cost.

Use of lamp or other electrical load of a wattage higher than installed or recommended by the factory, or use 

of inappropriate or inadequate wiring or circuit protection causes this warranty to become void.  Failure or destruction 
of the product resulting from abuse or unusual use and/or accidents is not covered by this warranty.  Code 3, Inc. 
shall in no way be liable for other damages including consequential, indirect or special damages whether loss is due 
to negligence or breach of warranty.

CODE 3, INC. MAKES NO OTHER EXPRESS OR IMPLIED WARRANTY INCLUDING, WITHOUT LIMITA-

TION, WARRANTIES OF FITNESS OR MERCHANTABILITY, WITH RESPECT TO THIS PRODUCT.

8

PROBLEMS OR QUESTIONS? CALL OUR TECHNICAL ASSISTANCE HOTLINE (314) 996-2800

WWW.CODE3PSE.COM

Code 3

®

 is a registered trademark of Code 3, Inc., a subsidiary of Public Safety Equipment, Inc.

Содержание LSS222

Страница 1: ...ered to the end user of this equipment IMPORTANT LSS222 Dual Stacked Beacon Contents Introduction 2 FeaturesandSpecifications 2 3 FlashPatterns 3 Dimensions 3 Current Draw 4 Installation Mounting 5 Wiring 5 Operation 6 Maintenance 6 Troublleshooting 6 Notes 6 7 Warranty 8 INSTALLATION OPERATION MANUAL ...

Страница 2: ...manufacturer s instructions before installing or using this device The vehicle operator should insure daily that all features of the device operate correctly In use the vehicle operator should insure the projection of the warning signal is not blocked by vehicle components i e open trunks or compartment doors people vehicles or other obstructions This equipment is intended for use by authorized pe...

Страница 3: ...riple Alter D 75FPM YES 16 Dynamic Flash D 150FPM YES 17 Double Flash D 150FPM YES 18 Double Flash D 75FPM YES 19 Single Flash D 375FPM YES 20 Single Flash D 150FPM YES 21 Single Flash D 75FPM YES 22 Dynamic Flash Phase 1 YES 23 Dynamic Flash Phase 2 YES 24 Modulation Action Flash NO 25 Modulation Action Flash NO 26 Rotator 50FPM YES 27 Rotator 75FPM YES 28 Rotator 125FPM YES 29 Rotator 250FPM YES...

Страница 4: ...4 LS222 Pipe Mount Permanent Mount Dimensions LS222 Magnetic Mount Flashing Current Draw Flashing Current Draw Amber Red Blue 85A Avg 1 0A Max Current Draw ...

Страница 5: ... beacon in place should the unit slide or move easily Permanent Mounting The permanent mount beacon provides a secure permanent installation Use the supplied foam gasket and screws to mount the beacon in the desired location Wire routing should be taken into consideration when choos ing a mounting location Pipe Mounting optional The beacon base will accept a standard 1 NPT pipe Hand tighten the be...

Страница 6: ... module Operation Synchronization Permanent Mount Only To sync two beacons configure both lights to display the same Phase 1 pattern With the power off connect the YELLOW wires from each lights together When the lights are activated their patterns will be synchronized To configure the two lightheads to alternate their patterns advance the pattern of either beacon to the Phase 2 mode of the current...

Страница 7: ...7 NOTES ...

Страница 8: ...ovidedtheyareinstalledandoperatedinaccordancewithmanufacturer srecommendations Code3 Inc guarantees all parts and components except the lamps to a period of 1 year LED Lighthead modules to a period of 5 years unless otherwise expressed from the date of purchase or delivery whichever is later Units demonstrated to be defective within the warranty period will be repaired or replaced at the factory s...

Отзывы: