3

PATTERN NO.

PATTERNS

SYNCHRONIZE

1

75FPM Triple Alter Phase 1

YES

2

75FPM Triple Alter Phase 2

YES

3

75FPM Quad Flash Phase 1

YES

4

75FPM Quad Flash Phase 2

YES

5

Double Flash 75FPM Phase 1 CA T13

YES

6

Double Flash 75FPM Phase 2 CA T13

YES

7

Double Flash 150FPM Phase 1 

YES

8

Double Flash 150FPM Phase 2

YES

9

Single Flash 75FPM Phase 1 CA T13

YES

10

Single Flash 75FPM Phase 2 CA T13

YES

11

Single Flash 150FPM Phase 1

YES

12

Single Flash 150FPM Phase 2

YES

13

Single Flash 375FPM Phase 1

YES

14

Single Flash 375FPM Phase 2

YES

15

Triple Alter D 75FPM

YES

16

Dynamic Flash D 150FPM

YES

17

Double Flash D 150FPM

YES

18

Double Flash D 75FPM

YES

19

Single Flash D 375FPM

YES

20

Single Flash D 150FPM

YES

21

Single Flash D 75FPM

YES

22

Dynamic Flash Phase 1

YES

23

Dynamic Flash Phase 2

YES

24

Modulation Action Flash

NO

25

Modulation Action Flash

NO

26

Rotator 50FPM

YES

27

Rotator 75FPM

YES

28

Rotator 125FPM 

YES

29

Rotator 250FPM

YES

30

NFPA Quad Flash

NO

31

Single Flash 75FPM CA T13

NO

32

Double Flash 75 FPM CA T13

NO

33

ECE 65 Double Flash Phase 1

YES

34

ECE 65 Double Flash Phase 2

YES

35

ECE 65 120FPM Single Flash Phase 1

YES

36

ECE 65 120FPM Single Flash Phase 2

YES

37

ECE 65 125FPM Rotator Flash

YES

38

Steady Burn

NO

39

Autorun (random)

NO

40

OFF

Flash Patterns:

Содержание LSS222

Страница 1: ...ered to the end user of this equipment IMPORTANT LSS222 Dual Stacked Beacon Contents Introduction 2 FeaturesandSpecifications 2 3 FlashPatterns 3 Dimensions 3 Current Draw 4 Installation Mounting 5 Wiring 5 Operation 6 Maintenance 6 Troublleshooting 6 Notes 6 7 Warranty 8 INSTALLATION OPERATION MANUAL ...

Страница 2: ...manufacturer s instructions before installing or using this device The vehicle operator should insure daily that all features of the device operate correctly In use the vehicle operator should insure the projection of the warning signal is not blocked by vehicle components i e open trunks or compartment doors people vehicles or other obstructions This equipment is intended for use by authorized pe...

Страница 3: ...riple Alter D 75FPM YES 16 Dynamic Flash D 150FPM YES 17 Double Flash D 150FPM YES 18 Double Flash D 75FPM YES 19 Single Flash D 375FPM YES 20 Single Flash D 150FPM YES 21 Single Flash D 75FPM YES 22 Dynamic Flash Phase 1 YES 23 Dynamic Flash Phase 2 YES 24 Modulation Action Flash NO 25 Modulation Action Flash NO 26 Rotator 50FPM YES 27 Rotator 75FPM YES 28 Rotator 125FPM YES 29 Rotator 250FPM YES...

Страница 4: ...4 LS222 Pipe Mount Permanent Mount Dimensions LS222 Magnetic Mount Flashing Current Draw Flashing Current Draw Amber Red Blue 85A Avg 1 0A Max Current Draw ...

Страница 5: ... beacon in place should the unit slide or move easily Permanent Mounting The permanent mount beacon provides a secure permanent installation Use the supplied foam gasket and screws to mount the beacon in the desired location Wire routing should be taken into consideration when choos ing a mounting location Pipe Mounting optional The beacon base will accept a standard 1 NPT pipe Hand tighten the be...

Страница 6: ... module Operation Synchronization Permanent Mount Only To sync two beacons configure both lights to display the same Phase 1 pattern With the power off connect the YELLOW wires from each lights together When the lights are activated their patterns will be synchronized To configure the two lightheads to alternate their patterns advance the pattern of either beacon to the Phase 2 mode of the current...

Страница 7: ...7 NOTES ...

Страница 8: ...ovidedtheyareinstalledandoperatedinaccordancewithmanufacturer srecommendations Code3 Inc guarantees all parts and components except the lamps to a period of 1 year LED Lighthead modules to a period of 5 years unless otherwise expressed from the date of purchase or delivery whichever is later Units demonstrated to be defective within the warranty period will be repaired or replaced at the factory s...

Отзывы: