TROUBLESHOOTING
Problem
Probable Cause
Remedy
Lighthead does not activate
a. No power to unit
a. Check wire for loose connection
b. Power input wire reversed
b. Reverse power wires
c. Damaged or shortaged cabling
c. Check cables for damage
d. Defective lighthead
d. Replace lighthead module
Lighthead is constantly ON
a. Control wire permanently
grounded or shorted to GND
a. Avoid permanent grounding of
control wire
LED module housings may become hot with extended use. Allow modules to cool completely
before attempting to remove.
WARNING!
Maintenance:
The beacons are completely sealed units designed to be maintenance free. Refer to the guide below for help
with troubleshooting. Should the unit be diagnosed as malfunctioning, remove unit and replace with a new
module.
Operation:
Synchronization (Permanent Mount Only):
To sync two beacons, confi gure both lights to display the same Phase 1 pattern. With the power off, connect
the YELLOW wires from each lights together. When the lights are activated, their patterns will be synchronized.
To confi gure the two lightheads to alternate their patterns, advance the pattern of either beacon to the Phase 2
mode of the current pattern. A maximum of 8 lights may be sychronized.
Setting the Flash Pattern (Magnetic base):
Depress the rocker switch on the lighter plug:
- Less than 1 second for the NEXT pattern
- 1 to 3 seconds for the PREVIOUS pattern
- 3 to 5 seconds for the DEFAULT pattern
- Greater than 5 seconds to TURN OFF the beacon
Setting the Flash Pattern (Permanent base):
Connect blue wire to black wire (chassis ground):
- Less than 1 second for the NEXT pattern
- 1 to 3 seconds for the PREVIOUS pattern
- 3 to 5 seconds for the DEFAULT pattern
- Greater than 5 seconds to TURN OFF the beacon