Page 6 of 12
Auto Siren Feature
By setting Dip switch #2 to the “on” position, Auto Siren is enabled. In this mode, the SIR1 siren tone will automatically turn on when Lighting
Level 3 is turned on. When Lighting Level 3 is later turned off, any siren tone that is on will also shut off. The SIR1 siren tone may be pro-
grammed as described below.
Programmable Siren Tones
The SIR1 and SIR2 are user programmable. They are preset at the factory as such: SIR1 – Wail and SIR2 – Yelp, To change the factory pre-
set, depress and hold the STBY button, then depress/release the desired SIR button to go to the next available tone. Once the desired tone is
chosen, release both buttons. Repeat for the other SIR buttons.
Programmable Air Horn Pitch Tones
There are two tones available for the Air Horn. To change, depress and hold the STBY button, then depress/release the Air Horn button. Once
the desired tone is chosen, release both buttons.
Auxiliary Light Control Buttons
There are four auxiliary light control buttons that the user can use as desired. To operate, depress/release once and the desired feature will be
enabled. Depress/release again and the feature will be disabled. The AUX3 and AUX4 buttons have special modes they can operate in that
can be enabled with Dip switches. If these modes are not set, AUX3 and AUX4 operate in default mode, which is the same as the other AUX
buttons. Below is a description of these two modes.
AUX3 - Momentary Active Mode
When Dip switch #3 is “on”, the AUX3 channel is only active while the AUX3 button is pressed. Once released, the AUX3 channel
will become inactive again.
AUX4 - Gun Lock Mode
When Dip switch #5 is “on”, pressing the AUX4 button will cause the AUX4 channel to become active for 10 seconds. After 10 sec-
onds, the AUX4 channel will become inactive again.
Keypad Backlight Dimming and Shut Off
There are four (4) levels of dimming on the hand-held controller keypad: Brightest, Bright, Dim, and Off. To initiate a change to the dimming
level hold the STBY button down for 5 or more seconds without pressing any other buttons on the keypad. The unit will change to the next dim
level (or Off if it is currently set at the lowest dimming level). If the STBY is depressed/released again within approximately two (2) seconds, the
dim changes to the next level. The user can depress/release the STBY button continuously within two (2) seconds to cycle through all dimming
levels. If the STBY button is not depressed/released within two (2) seconds, the dimming level is set. To initiate a change to the dimming level
the STBY button must again be held down for 5 or more seconds. The dimming level will remain set even after the unit has been turned off.
California Title 13 Compliance
By setting Dip switch #1 to the “on” position, the H
2
Covert operates in a California Title 13 Compliance mode. In this mode, Hyper Yelp, Hi-Lo,
Hyper-Lo, and Whoop siren tones are disabled. In addition, the Air Horn is disabled if Light Levels 2 or 3 are on.
Содержание H2 Covert
Страница 9: ...Page 9 of 12 Figure 3 ...