3. The on and off switchings of the vacuum cleaner will now be controlled by
the connected power tool. The vacuum cleaner will be switched on as soon as
the connected power tool is switched on. When the connected power tool is switched
off there will be about a 5-second delay before the vacuum cleaner is switched off.
Note:
The power tool socket must not be loaded with more than 2180 W.
Dry vacuuming
The wet and dry vacuum is usually delivered ready for dry vacuuming, with the cartridge
filter (11a) and filter retainer (11.b) already fitted. In other cases follow this procedure:
1. Make sure that the vacuum is unplugged from the mains.
2. Mount the cartridge filter (11a).
3. Secure the cartridge filter in place by turning the filter retainer
(11b) clockwise.
4. Fit the dust bag (12) over the inlet.
5. Refit the motor unit onto the container and fasten it with
the latches.
6. Screw the suction hose securely onto the container vacuum port (8).
7. Attach the appropriate accessory.
8. Plug the mains lead into a wall socket.
9. Switch the vacuum cleaner on by setting the power switch to the desired setting.
Wet Vacuuming
Warning:
Do not use the wet & dry vacuum to vacuum toxic, hazardous or flammable
substances/liquids.
Note:
Do NOT use the cartridge filter or dust bag when wet vacuuming.
Warning:
Always unplug the mains lead from the wall socket before any maintenance
or adjustments.
1. Remove the motor unit and fit the foam filter (13).
Slide the foam filter onto the filter basket making sure to
cover the entire filter basket.
2. Refit the motor unit onto the container and fasten it on
using the toggle latches.
3. Screw the suction hose securely onto the container
vacuum port (8).
4. Attach the accessory of your choice to the hose.
5. Plug the mains lead into a wall socket.
6. Start the machine using the power switch.
7. The water level within the container is regulated by a safety float valve.
When the container needs to be emptied, the safety valve stops suction and
the motor will race. Switch the motor off with the power switch. Open the drain
plug (7) to empty the container of any water.
Note:
Do not submerge the entire nozzle under the surface. Leave some space so
that air can also pass through when vacuuming a large amount of liquid.