- 7 -
level at operator’s position
(According to EN ISO 5395-1
Annex F & EN ISO 5395-2,
EN ISO 4871)
K=3dB(A)
Measured sound power level
Guaranteed Sound Power
level
(According to 2000/14/EC)
96.6B(A) K=1.83dB(A)
98 dB(A)
Vibration
(According to EN ISO 5395-1
Annex G & EN ISO 5395-2)
5.65m/s²
K=1.5 m/s²
5. ASSEMBLY
5.1 FOLDING HANDLE
1. Fix the lower handlebars into the unit body with a suitable spanner. (Fig.2A/Fig.2B/Fig.2C)
2. Lift the two locking levers to release the upper handlebars for folding. (Fig. 2D)
3. Push the locking lever closed to lock the handlebars in the operating position. (Fig.2E)
4. Adjust the tension by turning the lock nut with a suitable spanner. (Fig.2F)
5. Attach the cable-clamp to the position shown and then attach the cable. (Fig.2G)
Fig.2A Fig.2B Fig.2C
Fig.2D Fig.2E Fig.2F
Fig.2G