Installation
4
Moffat Cobra Series - CF4
©
Moffat Ltd, August 2012
Amendment 4
4. Correctly locate the appliance into its final
operating position and using a spirit level, adjust
the legs so that the unit is level and at the
correct height.
5. Connect the gas supply to the appliance.
6. Verify the operating pressure remains correct.
Please note that the outlet pressure is factory set
and is NOT to be adjusted
.
7. Check all gas connections for leakages using
soapy water or other gas detecting equipment.
NOTE:
The regulator supplied is convertible between
Natural Gas and LPG, but it’s outlet pressure is fixed
ex-factory and is NOT to be adjusted.
8. Turn ‘OFF’ the mains gas supply and bleed the
gas out of the appliance gas lines.
9. Turn ‘ON’ the gas supply and the appliance.
10.
Please note that the pilot flame size is factory set
and paint sealed
. Check that the pilot covers
the thermocouple. If the pilot needs adjusting,
this should be carried out by an qualified service
agent.
Flexible Hose Connection;
If a Gas Hose assembly is used to connect
this appliance, the hose and all fittings
must have a
minimum
¾
” (Natural Gas) or ½” (LPG)
inside bore diameter to ensure gas flow
rate capacity
required by this appliance is achieved.
This must be verified by the operating
pressure testing at the maximum gas sup-
ply demand condition.
The Gas Hose assembly should also be
classified for use in the commercial kitch-
en conditions, the appliance will be used
in.
Recommended Gas Hose Assembly Spec-
ification:
- AS/NZS 1869 Class B or D compliant or
equivalent, that meets the following
requirements:-
Assembly
This model is delivered completely assembled.
Ensure that the legs are securely attached.
NOTE:
This appliance is fitted with adjustable feet to enable
the appliance to be positioned securely and level.
This should be carried out on completion of the gas
connection. Refer to the 'Gas Connection' section.
Gas Connection
NOTE:
ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A
QUALIFIED SERVICE PERSON.
1. COBRA Model Fryers do not require an electrical
connection, they function totally on the gas
supply only.
2. It is essential that the gas supply is correct for the
appliance to be installed and that adequate
supply pressure and volume are available. The
following checks should therefore be made
before installation:-
a.
The Gas Type
the appliance has been
supplied for is shown on coloured stickers
located above the gas entry point and next
to the rating plate. Check that this is correct
for the gas supply the appliance is being
installed for. The gas conversion procedure is
detailed in the Service Manual.
b.
Supply Pressure
required for this appliance is
shown in the “Specifications” section of this
manual. Check the gas supply to ensure that
adequate supply pressure exists.
c.
Input Rate
of this appliance is also stated on
the Rating Plate fitted to the inside of the
access door and in the “Specifications”
section of this manual. The input rate should
be checked against the available gas supply
line capacity.
Particular note should be
taken if the appliance is being added to an
existing installation.
NOTE:
It is important that adequately sized piping runs
directly to the connection joint on the appliance,
with as few tees and elbows as possible to give
maximum supply volume.
3. A suitable joining compound which resists the
breakdown action of LPG must be used on eve-
ry gas line connection, unless compression fit-
tings are used.
The connection to the appliance is
3
/
4
” BSP male.
NOTE:
A Manual Isolation Valve must be fitted to the
individual appliance supply line.
WARNING:
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Class
Max Working
Pressure
at 23 ± 2
ºC
Working
Temperature
Range
Resistance
to Oil
B
7.0 kPa
- 20
ºC to +
125ºC
D
2.6 MPa
Oil resistant
lining and
cover.