6
Service Procedures
13
Moffat Cobra Series - CF4
©
Moffat Ltd, August 2012
Amendment 4
Section
Page
Number
6.1 Access .................................................................................................................................14
6.1.1 Control
Panel
................................................................................................................................... 14
6.2 Replacement
......................................................................................................................14
6.2.1 Thermocouple
(Gas
Control)
........................................................................................................ 14
6.2.2
Thermocouple (Flame Failure Valve) .......................................................................................... 15
6.2.3 Pilot
Injector
...................................................................................................................................... 15
6.2.4 Pilot
Burner
........................................................................................................................................ 15
6.2.5
Over-Temperature Safety Thermostat ......................................................................................... 15
6.2.6 Main
Burner
Injector
........................................................................................................................ 16
6.2.7 Main
Burners
..................................................................................................................................... 16
6.2.8
Gas Valve Removal ........................................................................................................................ 18
6.2.9
Gas Valve Re-Fitting........................................................................................................................ 19
6.2.10 Flame
Failure
Valve
......................................................................................................................... 20
6.3 Adjustment
/
Calibration ...................................................................................................21
6.3.1 Pilot
Flame
Adjustment
................................................................................................................... 21
6.3.2 Thermostat
Calibration
................................................................................................................... 21
6.3.3 Operating
Pressure
.......................................................................................................................... 22
WARNING:
A
LL
INSTALLATIONAND
SERVICE
REPAIR
WORK
MUST
BE
CARRIED
OUT
BY
QUALIFIED
PERSONS
ONLY
.
E
NSURE
GAS
SUPPLY
IS
SWITCHED
‘
OFF
’
BEFORE
SERVICING
.
A
LWAYS
CHECK
/
TEST
FOR
GAS
LEAKS
AFTER
SERVICE
REPAIRS
ON
THE
GAS
SYSTEM
.
Содержание cf4
Страница 1: ...Moffat Cobra Series CF4 Moffat Ltd August 2012 Amendment 4 Service Manual Gas Fryer Model CF4 ...
Страница 4: ...Moffat Cobra Series CF4 Moffat Ltd August 2012 Amendment 4 ...
Страница 30: ...8 Circuit Schematics 26 Moffat Cobra Series CF4 Moffat Ltd August 2012 Amendment 4 9 1 CF4 Fryer Schematic ...
Страница 38: ......