![Cobra cf4 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/cobra/cf4/cf4_service-manual_2630398014.webp)
5
Fault Finding
10
Moffat Cobra Series - CF4
©
Moffat Ltd, August 2012
Amendment 4
Fault
Possible Cause
Remedy
Set temperature not reached.
Gas supply fluctuating.
Thermostat out of calibration.
Placing food into oil too soon.
Too large a load.
Supply correct pressure.
Recalibrate thermostat.
(Refer Section 6.3.2).
Give the fryer more time to come
up to temperature before inserting
food.
Reduced load size will allow the
fryer to recover temperature quick-
er.
Oil too hot.
Thermostat out of calibration.
Re-calibrate thermostat.
(Refer Section 6.3.2).