Fault Finding
8
Moffat Cobra Series - CF4
©
Moffat Ltd, August 2012
Amendment 4
Fault
Possible Cause
Remedy
Pilot will not light.
No gas supply.
Gas pressure too low.
Knob on gas control won’t go
fully in.
Flame failure valve pilot button
will not go fully in.
Blocked pilot injector.
Ensure gas is connected and on
and bottles are not empty.
Check gas supply pressure.
(Refer Specifications Section).
Remove obstruction. Correct
control / wrapper mounting.
Replace gas control valve.
(Refer Section 6.2.8 / 6.2.9).
Replace flame failure valve.
(Refer to Section 6.2.10).
Clean or replace pilot injector.
(Refer Section 6.2.3).
Pilot goes out when knob released. Releasing knob before the
thermocouple heated.
Pilot flame too small.
(Refer Fault: Pilot Flame too Small)
Thermocouple faulty.
(Refer Fault Diagnosis 5.2.1)
Over-temperature thermostat
tripped reset or faulty.
(Refer Fault Diagnosis 5.2.1)
Gas control valve faulty.
Flame failure valve faulty.
Hold control in for longer (10 secs),
see if pilot will stay lit.
Correct fault.
Replace thermocouple.
(Refer Section 6.2.2).
Replace over-temperature
thermostat.
(Refer Section 6.2.5).
Replace gas control magnet.
Replace flame failure magnet.
Pilot flame small.
Gas pressure too low.
Pilot adjustment screw out of
adjustment.
Pilot injector restricted.
Check gas supply pressure.
(Refer Specifications Section).
Adjust pilot adjustment screw.
(Refer Section 6.3.1).
Clean pilot injector.
(Refer Section 6.2.3).
Pilot goes out when main burner
comes 'On'.
Incorrect gas pressure.
Faulty gas control.
Check supply / adjust pressure.
(Refer Specifications Section).
Replace gas control valve.
(Refer Section 6.2.10 / 6.2.11).
5.1 Fault Finding Chart
WARNING:
A
LL
INSTALLATION
AND
SERVICE
REPAIR
WORK
MUST
BE
CARRIED
OUT
BY
QUALIFIED
PERSONS
ONLY
.
I
MPROPER
INSTALLATION
,
ADJUSTMENT
,
ALTERATION
,
SERVICE
OR
MAINTENANCE
CAN
CAUSE
PROPERTY
DAMAGE
,
INJURY
OR
DEATH
.
R
EAD
THE
INSTALLATION
,
OPERATING
AND
MAINTENANCE
INSTRUCTIONS
THOROUGHLY
BEFORE
INSTALLING
OR
SERVICING
THIS
APPLIANCE
.
Содержание cf4
Страница 1: ...Moffat Cobra Series CF4 Moffat Ltd August 2012 Amendment 4 Service Manual Gas Fryer Model CF4 ...
Страница 4: ...Moffat Cobra Series CF4 Moffat Ltd August 2012 Amendment 4 ...
Страница 30: ...8 Circuit Schematics 26 Moffat Cobra Series CF4 Moffat Ltd August 2012 Amendment 4 9 1 CF4 Fryer Schematic ...
Страница 38: ......