7. MAINTENANCE
Disconnect from the power supply before completing any cleaning or maintenance.
1. Store the tool, instruction manual and accessories in a secure, dry place.
2. Keep the tool's air vents unclogged and clean at all times.
3. Remove dust and dirt regularly. Cleaning is best done with a rag or brush.
4. Never use caustic agents to clean plastic parts.
5. Check the machine for damage or signs of wear. If the tool starts to vibrate abnormally, immediately stop and
consult your service centre for repairs.
Caution
: Do not use cleaning agents to clean the plastic parts of the tool. A mild detergent on a damp cloth is
recommended. Keep water away from the blower.
8. TROUBLESHOOTING
Problem
Possible cause
Fault correction
Device does not start
Not connected to the power supply Connect to the plug the socket. Use an
RCD protected socket.
Power cord or plug are defective
Contact your Cobra service centre
Defective electrical component
Device does not reach full
power
Unsuitable extension cable
Use an extension cable to the correct
specification.
Vacuum function reduced
Clear the air vents. Check and empty the
bag for the vacuum.
Air vents are blocked
11