background image

1

UZY-6-B BLOWER KIT

P/N 900597-00 

Rev. NC, 10/2015

HEARTH PRODUCTS

KITS AND ACCESSORIES

KIT CONTENTS

1 ea. UZY-6-B Blower Assembly

1 ea. Mill-Pack

1 ea. Instruction Sheet

TOOLS NEEDED

Robertson (square) or Phillips (star) screwdriver

INSTALLATION INSTRUCTIONS FOR INSTALLING UZY-6-B REPLACEMENT BLOWER KIT 
FOR USE WITH WOOD-BURNING FIREPLACES LISTED IN TABLE 1

Blower Kit

Cat. No.

Model

Where Used

J8003

UZY-6-B Ladera™, Brentwood™ LV, WRT3820WS, WRT4820WS, 

BIS

® 

Nova and BIS Ultima

Table 1

INSTALLATION INSTRUCTIONS

Step 1.

  Open door, and remove the andirons, using a square or phillips 

screwdriver. Then remove front and bottom refractories.

Step 2.

  Unscrew the access plate located in the firebox floor (12 screws). 

Remove the access plate and the high heat cement used to seal it.

Step 3.

  Unplug the blower from the electric receptacle located on the 

right side of the fireplace.

Step 4.

 Unscrew the blower using a Robertson (square) or Phillips 

(star) screwdriver. The location of the (2) screws depends on 

the version of the blower installed 

(see 

Figure 1

)

. They can be 

at each end of the support bracket close to the floor (Version B) 

or on top of the support bracket near the left side (Version A). 

See 

Figure 1

.

Step 5.

  Take the blower out of the fireplace through the access opening.

Figure 1

       WARNING

The blower must be plugged directly into a properly grounded 
three-prong receptacle, 120 VAC, 60 Hz, single phase. Do not 
cut or remove the grounding prong from this plug.  
Installation must be in accordance with National Electrical 
Code, ANSI/NFPA 70 - latest edition.  In Canada, the current 
CSA C22.1 Canadian Electrical Code - latest edition.

GENERAL INFORMATION

This blower kit can easily be installed when the fireplace has a pre- installed 

junction box with 3 prong receptacle. You just have to plug it in.
If you encounter any problems, need clarification of these instructions or 

are not qualified to properly install this kit, contact your local distributor 

or dealer.
Read this instruction sheet in its entirety before beginning the installation.

ALL WARNINGS AND PRECAUTIONS IN THE INSTALLATION AND 

OPERATION MANUAL PROVIDED WITH THE APPLIANCE APPLY TO 

THESE INSTRUCTIONS.
SHUT DOWN THE APPLIANCE AND ALLOW IT TO COMPLETELY COOL 

BEFORE PROCEEDING.

 

 

Version A Unscrew these 

two screws

Version B

Or these screws

to remove the blower

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Summary of Contents for UZY-6-B

Page 1: ...support bracket close to the floor Version B or on top of the support bracket near the left side Version A See Figure 1 Step 5 Take the blower out of the fireplace through the access opening Figure 1 WARNING The blower must be plugged directly into a properly grounded three prong receptacle 120 VAC 60 Hz single phase Do not cut or remove the grounding prong from this plug Installation must be in a...

Page 2: ... to the back of the fireplace 1 Insert the blower backside down Steps 7 and 8 apply if the blower you removed is an older version Otherwise goto step 9 Step 7 There are two 1 spacers left after removing the old blower Leave them there because they are riveted although they won t be used anymore Step 8 Position the blower so that the new 1 spacer is touching the back of the fireplace and the blower...

Page 3: ...sion B ou audessus du support de ventilateur près du côté gauche version A Voir figure 1 Étape 5 Retirez le ventilateur par l ouverture de l âtre Figure 1 INFORMATIONS GÉNÉRALES Cet ensemble ventilateur peut être facilement installé quand le foyer comporte une boîte de jonction pré installée avec une prise à 3 broches Vous n avez qu à le brancher Si vous avez un problème quelconque avez besoin de ...

Page 4: ...ière vers le bas Les étapes 7 et 8 s appliquent seulement si le ventilateur que vous enlevez est une ancienne version Sinon allez à l étape 9 Étape 7 Il reste deux entretoises de 1 po après avoir retiré l ancien ven tilateur Laissez les en place car elles sont rivetées mais elles ne seront plus utilisées Étape 8 Positionnez le ventilateur de sorte que le nouvel espaceur de 1po inclus touché le dos...

Reviews: