background image

23

Nothing comes close to a Cobra

®

Limited 1-Year Warranty 

For Products Purchased In the U.S.A.

Cobra

®

Electronics Corporation warrants that its CobraMarine

Power Inverter, and 

the component parts thereof, will be free of defects in workmanship and materials 
for a period of one (1) year from the date of first consumer purchase. This warranty
may be enforced by the first consumer purchaser, provided that the product is utilized
within the U.S.A. 

Cobra

®

will, without charge, repair or replace, at its option, defective power inverters,

products or component parts upon delivery to the Cobra

®

Factory Service department,

accompanied by proof of the date of first consumer purchase, such as a duplicated
copy of a sales receipt. 

You must pay any initial shipping charges required to ship the product for warranty
service, but the return charges will be at Cobra

®

’s expense, if the product is repaired 

or replaced under warranty. This warranty gives you specific legal rights, and you 
may also have other rights which may vary from state to state.

Exclusions: This limited warranty does not apply: 1) To any product damaged by accident;
2) In the event of misuse or abuse of the product or as a result of unauthorized alterations
or repairs; 3) If the serial number has been altered, defaced, or removed; 4) If the owner
of the product resides outside the U.S.A.

All implied warranties, including warranties of merchantability and fitness for a
particular purpose are limited in duration to the length of this warranty. Cobra

®

shall

not be liable for any incidental, consequential or other damages; including, without
limitation, to damages resulting from loss of use or cost of installation. 

Some states do not allow limitations on how long an implied warranty lasts and/or 
do not allow the exclusion or limitation of incidental or consequential damages, so 
the above limitations may not apply to you.

For Products Purchased Outside the U.S.A.

Please contact your local dealer for warranty information.

22 English

Specifications

Continuous output power (1 hour) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2200w

Surge rating (0.1 second) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4400w

Peak efficiency (12V – 

1

2

load)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 88%

Efficiency (full load, 12V)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 83%

No load current draw  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 0.5A (12.6V)

Output waveform (resistive load)  . . . . . . . . . . . . . . . . . . . . . . . . . . . Modified sine wave

Output frequency  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ

Output voltage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109V – 120V

Input voltage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC

Alarm voltage (unload)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.2V – 10.8V

Shutdown voltage (unload)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.2V – 9.8V

Operating temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C – 40°C 

(32°F – 104°F)

Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40°C – 85°C 

(-40°F – 185°F)

Protection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Overload, short-circuit, overtemp,

reverse polarity, under/over voltage

Notes  

All protection is automatically recovered.  

To protect the battery, if the unit needs to be restarted after low voltage protection, 
the voltage of DC input should be above 12V.  

To extend the life of the fan, it will stop when there is no load. The speed of the fan
increases as the load increases.  

The unit is completely insulated in input and output for added safety.

Specifications

Operation

Warranty

Warranty

Содержание CPI M 2200

Страница 1: ...duct or not understand its many features please refer to this owner s manual If you require further assistance after reading this manual Cobra Electronics offers the following customer assistance serv...

Страница 2: ...22 Warranty Warranty 23 Customer Assistance Maintenance 24 Product Service 24 Accessories and Order Form 26 Controls Indicators and Product Features Introduction Table of Contents Introduction Featur...

Страница 3: ...atements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment where gas and battery fumes are presen...

Страница 4: ...rous voltages are present at the battery terminals This problem does not occur with the vast majority of battery operated equipment Most use a separate charger or transformer that is plugged into the...

Страница 5: ...be terminated with a lug or other connector that provides a secure low resistance connection For example if the power source is a battery the cable must be terminated with a battery terminal that cla...

Страница 6: ...han longer DC wires cables CAUTION To avoid fire do not cover or obstruct ventilation openings Do not install inverter in a zero clearance compartment Overheating may result CAUTION The inverter must...

Страница 7: ...ssential between the battery and inverter This is so it can deliver the maximum amount of energy to the load Use only copper wire Aluminum wire has about 1 3 more resistance than copper wire of the sa...

Страница 8: ...es and should be performed by a qualified electrician CAUTION Do not connect the inverter and another AC source such as a generator or utility power to the AC wiring at the same time The inverter will...

Страница 9: ...r for a specified length of time Example Reserve capacity a battery with a reserve capacity of 180 minutes can deliver 25 amperes for 180 minutes before it is completely discharged Example Ampere hour...

Страница 10: ...the Remote On Off Switch assembly and cable does not interfere with the driver or a passenger Be sure there is adequate clearance behind the panel before drilling or cutting 2 Cut out the mounting te...

Страница 11: ...o turn the inverter On or Off from a convenient location when the inverter is installed in an out of reach location Be sure to have your power inverter and Remote On Off Switch properly installed befo...

Страница 12: ...r and Protection Indicators The Power and Protection Indicators include along with an audible alarm an over temperature indicator an amps meter a volts meter and an overload indicator Over Temperature...

Страница 13: ...ut voltage exceeds 12V 0 3V The inverter will also shut down if the input voltage exceeds 15 75V 0 75V This protects the inverter against excessive input voltage Although the inverter has protection a...

Страница 14: ...rranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty Cobra shall not be liable for any incidental consequential or other damages incl...

Страница 15: ...to prevent accumulation of dust and dirt At the same time tighten the screws on the DC input terminals Be sure vents and fans are free of dust or debris Product Service If you have any questions about...

Страница 16: ...y products includes CB Radios microTALK Radios Radar Laser Detectors Safety Alert Traffic Warning Systems Accessories GPS Global Positioning System HighGear Accessories Name Address No P O Boxes City...

Отзывы: