background image

Plug In Directly

3

Nothing comes close to a Cobra

®

2

English

WARNING  Power inverters contain components that may produce arcs 
or sparks. To prevent fire or explosion, do not install the inverter in areas 
or compartments containing batteries or flammable materials or in locations 
that require ignition-protected equipment.

WARNING To reduce the risk of fire, do not cover or obstruct the ventilation
openings. Do not install inverter in zero-clearance compartment.

Caution: Rechargeable Appliances

Certain chargers for small nickel cadmium batteries can be damaged if connected to
the CobraMarine

M2200 Power Inverter. Two (2) particular types of equipment are

prone to this problem: 

1. Small battery-operated appliances such as flashlights, 

razors, and night lights that can be plugged directly into 
an AC receptacle to recharge.

2. Certain battery chargers for battery packs used in hand 

power tools. These chargers have a WARNING label stating 
that dangerous voltages are present at the battery terminals.

This problem does not occur with the vast majority of battery-operated equipment.
Most use a separate charger or transformer that is plugged into the AC receptacle 
and produces a low voltage output. If the label on the AC adapter or charger states 
that it produces a low voltage AC or DC output (less than 30 volts), the inverter 
will have no problem powering the adapter safely.

CobraMarine

M2200 Output Waveform

The output waveform is referred to as “square wave” or “modified sine wave.” It is a
stepped waveform designed to have characteristics similar to the sine wave shape of
utility power. A waveform of this nature is suitable for most AC loads (including linear
and switching power suppliers used in electronic equipment, transformers and motors).
Some very sensitive electronic equipment may not operate satisfactorily on “square 
wave” or “modified sine wave.”

Ground Fault Circuit Interrupter (GFCI) Outlet

Test the GFCI periodically to make sure it is operating properly 
(see page 16 for details).

Important Safety Information

Introduction

Important Safety Information

Introduction

Dangerous Voltages

Содержание CPI M 2200

Страница 1: ...duct or not understand its many features please refer to this owner s manual If you require further assistance after reading this manual Cobra Electronics offers the following customer assistance serv...

Страница 2: ...22 Warranty Warranty 23 Customer Assistance Maintenance 24 Product Service 24 Accessories and Order Form 26 Controls Indicators and Product Features Introduction Table of Contents Introduction Featur...

Страница 3: ...atements identify conditions that could result in personal injury or loss of life General Precautions 1 Never install the inverter in a boat s engine compartment where gas and battery fumes are presen...

Страница 4: ...rous voltages are present at the battery terminals This problem does not occur with the vast majority of battery operated equipment Most use a separate charger or transformer that is plugged into the...

Страница 5: ...be terminated with a lug or other connector that provides a secure low resistance connection For example if the power source is a battery the cable must be terminated with a battery terminal that cla...

Страница 6: ...han longer DC wires cables CAUTION To avoid fire do not cover or obstruct ventilation openings Do not install inverter in a zero clearance compartment Overheating may result CAUTION The inverter must...

Страница 7: ...ssential between the battery and inverter This is so it can deliver the maximum amount of energy to the load Use only copper wire Aluminum wire has about 1 3 more resistance than copper wire of the sa...

Страница 8: ...es and should be performed by a qualified electrician CAUTION Do not connect the inverter and another AC source such as a generator or utility power to the AC wiring at the same time The inverter will...

Страница 9: ...r for a specified length of time Example Reserve capacity a battery with a reserve capacity of 180 minutes can deliver 25 amperes for 180 minutes before it is completely discharged Example Ampere hour...

Страница 10: ...the Remote On Off Switch assembly and cable does not interfere with the driver or a passenger Be sure there is adequate clearance behind the panel before drilling or cutting 2 Cut out the mounting te...

Страница 11: ...o turn the inverter On or Off from a convenient location when the inverter is installed in an out of reach location Be sure to have your power inverter and Remote On Off Switch properly installed befo...

Страница 12: ...r and Protection Indicators The Power and Protection Indicators include along with an audible alarm an over temperature indicator an amps meter a volts meter and an overload indicator Over Temperature...

Страница 13: ...ut voltage exceeds 12V 0 3V The inverter will also shut down if the input voltage exceeds 15 75V 0 75V This protects the inverter against excessive input voltage Although the inverter has protection a...

Страница 14: ...rranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty Cobra shall not be liable for any incidental consequential or other damages incl...

Страница 15: ...to prevent accumulation of dust and dirt At the same time tighten the screws on the DC input terminals Be sure vents and fans are free of dust or debris Product Service If you have any questions about...

Страница 16: ...y products includes CB Radios microTALK Radios Radar Laser Detectors Safety Alert Traffic Warning Systems Accessories GPS Global Positioning System HighGear Accessories Name Address No P O Boxes City...

Отзывы: