![Cobalt Digital Inc +EAS Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/cobalt-digital-inc/eas/eas_manual-supplement_2629780008.webp)
6
EAS OPTION (+EAS) MANUAL SUPPLEMENT
OPT-SW-PHXEAS-MS (V1.1)
(continued)
• Activity Log Display
Displays a log of the four most recent EAS insertion actions.
Provides controls for setting the serial comms details for the
interface between the external EAS system and the +EAS card/
device. Also shows the message text and severity level for a
queued message.
EAS > Interface
• Message Displays
Displays queued text string as well as associated severity status. Clear
allows status display and the corresponding message to be cleared. If a
crawl is currently in progress, clicking Clear Queued Message(s) will stop
the crawl immediately.
• COMM (Serial) Setup Controls
For EAS Rx, sets COMM receive for port, bit rate and parity as shown.
Note: Where rear module exposes only one COMM port, set control here to
use COM 1.
Table 1
+EAS Option Control List and Descriptions — continued
In the example here, log shows a
complete cycle for one message event,
consisting of a crawl start and crawl stop.
Содержание +EAS