EAS OPTION (+EAS) MANUAL SUPPLEMENT

OPT-SW-PHXEAS-MS (V1.1)

Where +EAS is licensed for a card/device, the Event Setup > 
Event Triggers
 sub-tab has added choices associated with EAS 
actions. 

An added EAS trigger column exposes EAS actions that can be 
used as triggers to activate other actions. These triggers and 
actions can be used with other card/device attributes to step into 
and out of EAS modes and normal operation (as shown in the 
example below). The Event Action column also has choices that 
allow actions upon other triggers (such as GPI) to start and stop 
EAS (also shown in an example below).

Event Setup Controls

Table 1

+EAS Option Control List and Descriptions — continued

In the example here for Event 3 and Event 4, when a Crawl Start or Crawl Stop event has been detected, these events can 
serve as triggers to respectively invoke user preset “Go to EAS Audio Route” or “Go to Norm1A Audio Route”. These presets 
would be user-defined presets that perform special audio routing when a crawl is active, and resume to normal after the crawl 
has stopped.

Note: • Refer to Product Manual for detailed descriptions of the Event Setup tab and its sub-tabs, which contains 

important information regarding the use of event presets and actions.

In the example here for Event 1 and Event 2, GPI 1 is being used to start (and optionally) stop the crawl when 

EAS > General 

Setup

 is set to use Event Triggered operation. Note that while the Event 2 EAS Stop Trigger is not necessary to stop the crawl, 

the defined event here is useful should the need arise to abort the crawl sooner than its full content playout (as in the case of an 
erroneous “false alarm”). (A GPI correlated to an EAS Stop Trigger can be used to immediately stop a crawl even if all the crawl 
text has not yet been displayed.) Also note that EAS crawl for a given message ceases after the Crawl Loop Count is exhausted. 

Note: Although EAS Start Trigger starts an EAS text crawl, if no EAS message has been received, no text crawl will be generated.

Содержание +EAS

Страница 1: ...Galen Drive Champaign IL 61821 Voice 217 344 1243 Fax 217 344 1245 www cobaltdigital com OPT SW PHXEAS MS V1 1 Cobalt Digital Inc Emergency Alert System Text Crawl Generation Option EAS Manual Supple...

Страница 2: ...d for inaccuracies Furthermore Cobalt Digital Inc reserves the right to make changes to any products herein to improve readability function or design Cobalt Digital Inc does not assume any liability a...

Страница 3: ...edded in the received serial data are commands which set the message severity to be shown by the keyed crawl severity is correlated to user specified text color and background color for the crawl User...

Страница 4: ...be installed in order to use the EAS option Consult Rear Modules in card Product Manual or the card s web page for rear module assortment and descriptions available for the card Figure 2 Typical Inte...

Страница 5: ...e the Serial Number of your card displayed in the Card Info pane when contacting us for your feature key A key is tied to the card s serial number and will only work with that card Please indicate if...

Страница 6: ...S Figure 3 shows the typical serial coding used in a Sage ENDEC message sent by the device to be received as encoded text by a receiver such as EAS Present in typical EAS serial data received by optio...

Страница 7: ...ere this is a concern a GPI signal is typically provided as a ready go signal to activate the crawl See Event Setup Controls p 10 for an example of GPI triggering setup Immediate EAS text string will...

Страница 8: ...plays queued text string as well as associated severity status Clear allows status display and the corresponding message to be cleared If a crawl is currently in progress clicking Clear Queued Message...

Страница 9: ...e burn in at top of image For SD usage burn ins positioned near the top of the active image will impinge on and corrupt line 21 closed captioning waveform Make certain burn in is not positioned in thi...

Страница 10: ...pically it is recommended to have Character Opacity text set at the maximum setting for optimal readability in most cases Table 1 EAS Option Control List and Descriptions continued Crawl insertion spa...

Страница 11: ...t Pressing Confirm and confirming with prompt immediately starts the burn in insertion on the output raster Selection sets the type of message to be inserted in manual test Note The manual EAS entry f...

Страница 12: ...oute These presets would be user defined presets that perform special audio routing when a crawl is active and resume to normal after the crawl has stopped Note Refer to Product Manual for detailed de...

Страница 13: ...ides the logo graphic used by the card device The conversion consists of an online tool that takes in a png and outputs the image bin file which is then uploaded to the card device as described in the...

Страница 14: ...ptions continued Positioning with H and V controls at zero origin Positioning with H and V controls both at 50 Origin 0 0 x 100 y 100 Station ID Logo Insertion Setup Example A card device GPI is ideal...

Страница 15: ...does not work EAS Start bound to other action such as GPI For manual insertion mode EAS Manual EAS Entry Generate Manual EAS Message EAS Mode must be set to Immediate See EAS General Setup p 5 If EAS...

Страница 16: ...sible in output raster Insertion positioned too low in raster for format being carried On the EAS Interface subtab if the Vertical Position control is set too close to maximum 100 0 the crawl may not...

Страница 17: ......

Страница 18: ...Cobalt Digital Inc 2506 Galen Drive Champaign IL 61821 Voice 217 344 1243 Fax 217 344 1245 www cobaltdigital com...

Отзывы: