14
EAS OPTION (+EAS) MANUAL SUPPLEMENT
OPT-SW-PHXEAS-MS (V1.1)
Entire message (from start
to end) not displayed, or
message is truncated
Message start or stop
occurs before message is
ready or ended
An EAS Event Triggered mode should be used where serial
data make take a relatively long time to accumulate in the
card/device hosting EAS. GPI triggering can be used to then
launch to insertion.
Also available is using the Crawl Start Delay control to hold off
on immediate message playout. See EAS > General Setup,
p. 5. for more information.
Log indicates insertion
performed, but insertion is
not visible in output raster
Insertion positioned too low
in raster for format being
carried
On the EAS > Interface subtab, if the Vertical Position control
is set too close to maximum (100.0), the crawl may not be
visible in the active image area. See EAS > Crawl, p. 7 for
more information.
Closed captioning on SD
output raster shows errors
or visible corruption during
EAS insertion
Insertion vertical position
impinging on line 21 closed
captioning space
For SD usage, burn-ins positioned near the top of the active
image will impinge on and corrupt line 21 closed-captioning
waveform. Make certain burn-in is not positioned in this area.
(Position control set greater than 1.0 avoids this issue.)
Table 2