BBG1003UDXADDA-OM (V1.2)
BBG-1003-UDX-ADDA PRODUCT MANUAL
3-47
Setup/Operating Instructions
BBG-1003-UDX-ADDA Function Menu List and Descriptions
(continued)
• Extraction Flow Control
Allows communication between device transmit and receiving
destinations to regulate data receive as follows:
• No Flow Control: Data is transmitted without buffering or checking
to see if data is being transmitted faster than it can be received.
• XON / XOFF: The device UART Rx will acknowledge from the
receiving system whether it can or cannot accept data at current bit
rate.
• Hold Break: Device, if receiving notification from the receiving
system that it is close to not being able to accept new data, tells the
device to hold. Device releases this hold when the receiving system
removes the break command, indicating destination is now ready
again to accept new data.
• Bit Rate/ Parity Gen Control
For both Rx and Tx, sets UART for bit rate and parity as follows:
• Bit Rate: Sets Tx/Rx bit rate from 1 of 5 speeds ranging from 9600
to 230400 Baud.
• Parity: Sets device Rx to expect odd or even parity from incoming
data, and sets device Tx to generate a parity bit to satisfy selected
parity. Where parity is set, incoming data not conforming to parity
selection is rejected.
Table 3-2