BBG1003UDXADDA-OM (V1.2)
BBG-1003-UDX-ADDA PRODUCT MANUAL
3-13
Setup/Operating Instructions
BBG-1003-UDX-ADDA Function Menu List and Descriptions
Provides up/down/cross-converter, aspect ratio
controls, and user H/V controls.
Scaler
• Scaler Enable Control
Enables or disables Scaler function.
Note: When scaler is disabled, all ancillary data is passed from input to
output intact. If the scaler is enabled, ancillary data such as
timecode and closed captioning must be set for re-insertion as
desired. See Timecode (p. 3-39) and Closed Captioning (p. 3-44)
for more information about insertion into scaled output video.
• Input/Output Video Status
Displays signal format/status sent to scaler and output format/status.
If invalid or no signal is present, none is displayed.
• Output Format Selector
Provides conversions to formats as shown.
• Scaler Follow AFD Enable/Disable
Sets scaler to automatically follow incoming AFD ARC control.
Note: • The Scaler follow AFD control also appears on the AFD/WSS/VI
tab and is mutually ganged with the selection performed on either
tab. Refer to AFD/WSS/VI Code Insertion Controls (p. 3-33) for
more information.
• 3:2 Alignment Optimization Selector
Provides selection to optimize 3:2 pulldown conversion where timecode
or other selections shown are to be relied upon to indicate frame
transitions.
Note: If input video timecode or other marker cannot be relied upon for
accurate and precise frame marking, leave control set to Free Run.
Table 3-2
BBG-1003-UDX-ADDA Function Menu List — continued
fld fld fld fld fld
fld fld fld fld fld
A-Frame alignment to 6Hz pulse via GPI
In the example below, A-frame is aligned using 6Hz pulse imported via
GPI.